AI Article Synopsis

  • The orthogonal pressurized planar electrochromatography (OPPEC) is a 2-D separation method combining electrophoresis and chromatography for effective substance separation.
  • This technique allows for continuous input of sample solutions, efficiently separating and collecting different components based on their electrophoretic mobility.
  • The paper introduces a new approach using OPPEC for substances with similar mobility, highlighting its benefits over traditional column chromatography in separating complex mixtures.

Article Abstract

The orthogonal pressurized planar electrochromatography (OPPEC) is an example of 2-D separation technique, in which two simultaneous and orthogonal processes of electrophoresis and chromatography are involved in the separation mechanism. In the case of preparative separation of substances characterized by different electrophoretic mobility, such separation system can be constantly fed with the sample solution and the separated components can be constantly collected at its outlet. In the paper, as opposed to the previous studies, we discuss the capabilities of OPPEC technique for preparative separation of substances characterized by the same electrophoretic mobility. According to the proposed solution, the separation system can be periodically fed with the sample solution and separated components can be collected alternately at its outlet. The advantages of this new approach over the column chromatography with regard to the separation of complex mixtures have been signaled.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2017.03.088DOI Listing

Publication Analysis

Top Keywords

sample solution
12
preparative separation
12
orthogonal pressurized
8
pressurized planar
8
planar electrochromatography
8
separation
8
separation substances
8
substances characterized
8
characterized electrophoretic
8
electrophoretic mobility
8

Similar Publications

Purpose: The volume of the vitreous chamber varies with the size of the eye. The space created in the vitreous cavity by a vitrectomy is called the vitrectomized space. The volume of the vitrectomized space is strongly correlated with the axial length of the eye.

View Article and Find Full Text PDF

This study evaluated a novel ex situ passive sampling biomimetic extraction (BE) method to estimate toxic potency in sediments. Gas chromatography with flame ionization detection (GC-FID) analysis of polydimethylsiloxane fibers equilibrated with field sediments was used to quantify bioavailable polyaromatic hydrocarbons (PAHs) and other unresolved, site-specific contaminant mixtures. This method is biomimetic because contaminants partition to the fiber based on hydrophobicity and abundance, and GC-FID quantification accounts for all constituents absorbed to the fiber that may contribute to toxicity.

View Article and Find Full Text PDF

Background: Online malicious attempts such as scamming continue to proliferate across the globe, aided by the ubiquitous nature of technology that makes it increasingly easy to dupe individuals. This study aimed to identify the predictors for online fraud victimization focusing on Personal, Environment and Behavior (PEB).

Methods: Social Cognitive Theory (SCT) was used as a guide in developing the PEB framework.

View Article and Find Full Text PDF

In the modern age, half of the population is facing various chronic illnesses due to glucose maintenance in the body, major causes of fatality and inefficiency. The early identification of glucose plays a crucial role in medical treatment and the food industry, particularly in diabetes diagnosis. In the past few years, non-enzymatic electrochemical glucose sensors have received a lot of interest for their ability to identify glucose levels accurately.

View Article and Find Full Text PDF

Nicotinamide adenine dinucleotide is a crucial coenzyme in cellular metabolism and is implicated in various diseases. This work introduces an electrochemical bioanalytical method utilizing solution-phase formate dehydrogenase (CbFDH) for detecting its oxidized form (NAD) in human blood plasma samples. The detection mechanism involves the catalytic conversion of NAD to NADH, facilitated by CbFDH in the presence of formate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!