AI Article Synopsis

  • Rat caudal discs are ideal for studying interbody fusion due to their similarity to human discs in structure and function.
  • In a study with female Sprague-Dawley rats, researchers performed interbody fusion and evaluated the results through radiological, histological assessments, and mechanical testing.
  • The findings showed successful fusion with significant bone formation and increased bending stiffness in fused segments, confirming the model's effectiveness for future research on fusion treatments.

Article Abstract

Background: Of the proposed animal interbody fusion models, rat caudal discs have gained popularity in disc research due to their strong resemblance to human discs with respect to geometry, composition and mechanical properties. The purpose of this study is to demonstrate an efficient, repeatable and easily accessible animal model of interbody fusion for future research into mechanical testing and graft materials.

Methods: Twelve 12-week-old female Sprague-Dawley (SD) rats underwent caudal interbody fusion of the third and fourth coccygeal vertebrae of the tail. Serial radiological evaluation, and histological evaluation and manual palpation after sacrifice were performed to assess the fusion quality. Mechanical testing of functional units (FUs) of non-operated and operated segments was compared using a three-point bending test.

Results: At postoperative 12 weeks, callus formation was observed at the fusion sites in all rats, with the mean radiological evaluations of 2.75/3 according to the Bransford classification. Newly formed bone tissue was also observed in all rats with the mean histological score of 5.85/7, according to the Emery grading system. No palpable gaps and obvious change of bending stiffness was observed in the operated segments. The mean bending stiffness of the FUs was statistically higher than that of the control FUs (26.57 ± 6.71 N/mm vs. 12.45 ± 3.21 N/mm, p < 0.01).

Conclusion: The rat caudal disc interbody fusion model proved to be an efficient, repeatable and easily accessible model. Future research into adjuvant treatments like growth factor injection and alternative fusion materials under conditions of osteoporosis using this model would be worthwhile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6138589PMC
http://dx.doi.org/10.1016/j.bj.2016.07.002DOI Listing

Publication Analysis

Top Keywords

interbody fusion
16
mechanical testing
12
operated segments
8
bending stiffness
8
fusion
6
characterization novel
4
novel caudal
4
caudal vertebral
4
interbody
4
vertebral interbody
4

Similar Publications

Objectives: The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.

View Article and Find Full Text PDF

Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).

View Article and Find Full Text PDF

Prone Transpsoas Lumbar Interbody Fusion for Degenerative Disc Disease.

JBJS Essent Surg Tech

January 2025

Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.

Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.

View Article and Find Full Text PDF

Background: Degenerative lumbar diseases (DLDs) often have significant impacts on patients' quality of life, particularly when cage retropulsion (CR) occurs following lumbar interbody fusion (LIF). In this study, we conducted a meta-analysis to assess the risk factors associated with CR after LIF.

Methods: We retrieved literatures analyzing the risk factors associated with CR following LIF from seven databases.

View Article and Find Full Text PDF

Evaluation of Healthcare Outcomes of Patients Treated with 3D-Printed-Titanium and PEEK Cages During Fusion Procedures in the Lumbar Spine.

Med Devices (Auckl)

January 2025

MedTech Epidemiology and Real-World Data Science, Johnson & Johnson, Raynham, Massachusetts & New Brunswick, New Jersey, USA.

Purpose: The objective of this observational, real-world study was to describe reoperation, revision, index healthcare utilization and hospital costs among patients treated with PEEK (polyetheretherketone) or 3D-printed-titanium cages during lumbar/lumbosacral posterior fusion procedures, either TLIF (transforaminal lumbar interbody fusion) or PLIF (posterior lumbar interbody fusion). Statistical comparisons were not conducted.

Methods: This was a descriptive, retrospective, observational study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!