Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Early detection of patients colonised with carbapenemase-producing Enterobacteriaceae (CPE) is crucial for implementing proper infection control measures. Here we evaluated the biological performance of the Xpert Carba-R v2 (Cepheid) in the daily workflow of a hygiene unit in a country with a low CPE prevalence. Patients repatriated from countries known for high CPE prevalence or contact patients of a known CPE carrier were targeted as being 'high-risk patients' for CPE carriage. Between September 2015 and March 2016, 241 'high-risk patients' for CPE carriage were screened using the Xpert Carba-R v2 and by plating on chromID CARBA Smart medium (bioMérieux) with and without ertapenem-containing enrichment culture for 24 h. Of these patients, 81.7% were previously hospitalised abroad and 18.3% were contact patients of known CPE carriers. The Xpert Carba-R v2 was able to detect 12 OXA-48-like, 1 KPC and 1 OXA-48-like/NDM carriers. For 2 of the 14 Xpert Carba-R v2-positive samples, cultures remained negative even on two additional screenings (performed at Days 4 and 7). The Xpert Carba-R v2 presents 100% sensitivity, 99.13% specificity, 85.71% positive predictive value and 100% negative predictive value. This study demonstrated that the Xpert Carba-R v2 kit is well adapted for rapid screening of high-risk patients even in low prevalence regions (in <1 h versus 24/48 h for culture). This assay may guide infection control programmes to limit the spread of CPE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijantimicag.2017.01.025 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!