The integration of ion mobility spectrometry (IMS) with a trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform-based double multiplexing which significantly improves the signal-to-noise ratio and duty cycle of the ion mobility-Orbitrap mass spectrometry (IM-Orbitrap MS) platform. However, artifacts and noise in the demultiplexed data significantly reduce the data quality and negate the benefits of multiplexing. We propose a new approach that identifies the true IM peaks and helps in eliminating the artifacts in the demultiplexed data leading to a decrease in false identifications in subsequent data processing. After the application of the algorithm, the quality of the IM-Orbitrap MS measurements was greatly improved because of the reduction in artifacts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c7an00289k | DOI Listing |
Transl Vis Sci Technol
January 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.
Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.
Lab Chip
January 2025
Institute of Translational Medicine, Department of Health Sciences and Technology, ETH Zürich, 8092 Zürich, Switzerland.
Proteases, an important class of enzymes that cleave proteins and peptides, carry a wealth of potentially useful information. Devices to enable routine and cost effective measurement of their activity could find frequent use in clinical settings for medical diagnostics, as well as some industrial contexts such as detecting on-line biological contamination. In particular, devices that make use of readouts involving magnetic particles may offer distinct advantages for continuous sensing because material they release can be magnetically captured downstream and their readout is insensitive to optical properties of the sample.
View Article and Find Full Text PDFTheranostics
January 2025
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA.
Ultrasound-induced thermal strain imaging (US-TSI) is a promising ultrasound imaging modality that has been demonstrated in preclinical studies to identify a lipid-rich necrotic core of an atherosclerotic plaque. However, human physiological motion, e.g.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Electrical Power and Machines Engineering, Higher Institute of Engineering, El-Shorouk Academy, El-Shorouk City, Cairo, Egypt.
Photovoltaic (PV) modules may encounter nonuniform situations that reduce their useable power volume, causing ineffective maximum power point tracking (MPPT). Moreover, due to the incorporation of bypass diodes, power-voltage (P-V) graph has multi-peaks when each component of the module receives different solar irradiation. This paper proposes a solution to this problem using an arithmetic optimization algorithm (AOA) for MPPT in PV systems operating in nonuniform situations.
View Article and Find Full Text PDFAm J Phys Med Rehabil
November 2024
PhD, Associate Professor of Physical Therapy, Basic Sciences Department, Faculty of Physical Therapy, Cairo University, Giza, Egypt.
Objective: While ultrasound therapy is common for carpal tunnel syndrome, the relative merits of thermal versus pulsed ultrasound remain unclear. This study compares their therapeutic effects.
Design: Randomized, double-blinded, placebo-controlled trial.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!