The Sternum-Nipple Distance is Double the Nipple-Inframammary Fold Distance in Macromastia.

Ann Plast Surg

From the *Division of Plastic and Reconstructive Surgery, School of Medicine, Louisiana State University Health Sciences Center, New Orleans, LA; and †Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA.

Published: June 2017

Background: Reduction mammaplasty is one of the most commonly performed plastic surgery operations. For a majority of techniques, the most common long-term complication is pseudoptosis. It has previously been proposed that upper breast suspensory ligaments (SL) are weaker than lower breast SL. We tested this hypothesis through anthropometry of the proxies for upper and lower SL strength: the sternal notch-nipple (SN-N) distance and the nipple-inframammary fold (N-IMF) distance, respectively.

Methods: An institutional review board-approved retrospective review of patients undergoing reduction mammoplasty in an academic faculty practice between 2008 and 2015 was conducted. Patient demographics included age, race, and body mass index (BMI); patient comorbidities included smoking status, diabetes, and hypertension. Breast anthropometric measurements included SN-N and N-IMF. Sternal notch-nipple was used as the primary metric of the upper SL strength, whereas N-IMF was used as the primary metric of the lower SL strength. Intraoperative details included reduction technique and resection mass. Postoperative complications were recorded, including nipple areola complex necrosis and hematoma. Linear regression analysis was performed with the primary endpoint of the relationship between SN-N and N-IMF distance in macromastia.

Results: Data from 208 patients, totaling 400 individual breast measurements, were collected. The mean SN-N length was 35.1 cm, mean N-IMF length was 16.0 cm, and mean resection weight was 1094 g. Linear regression found that N-IMF distance could be predicted as 45% of the SN-N distance (N-IMF = 0.454 * SN-N). This was a strong relationship, demonstrated by univariate analysis of SN-N and N-IMF (R, 0.624; P < 0.001). A Wise pattern was used in 89.9% of cases; an inferior pedicle was used in 83.7% of cases. Nipple areola complex necrosis occurred in 15 breasts (3.75%). Sternal notch-nipple (R, 0.127; P = 0.011) and N-IMF (R, 0.119; P = 0.017) were both predictive of nipple areola complex necrosis (Table 4).

Conclusions: In our series, the N-IMF distance increased 0.45 cm for every 1 cm increase in the SN-N distance. This relationship strengthens our primary hypothesis that the lower pole ligaments stretch at a significantly slower rate than the upper pole ligaments. Taking this into consideration, we suggest that surgeons seeking to minimize pseudoptosis rates should favor techniques that minimally disrupt the lower SL.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0000000000001031DOI Listing

Publication Analysis

Top Keywords

n-imf distance
16
sternal notch-nipple
12
sn-n distance
12
sn-n n-imf
12
nipple areola
12
areola complex
12
complex necrosis
12
n-imf
10
nipple-inframammary fold
8
distance
8

Similar Publications

Implant-based breast reconstruction (IBBR) is increasingly favored over autologous reconstruction due to its procedural simplicity and recovery benefits. Conducting this reconstruction using either the subpectoral or prepectoral planes has varied aesthetic outcomes. This study utilizes VECTRA XT 3D imaging to objectively assess breast symmetry differences between these surgical techniques.

View Article and Find Full Text PDF

Background: The iPhone contains a high-fidelity 3-dimensional (3D) scanner and is widely distributed in the United States. Presently, 3D analysis of the breast necessitates ownership of cost-prohibitive cameras and software packages such as the Vectra (Canfield Scientific Inc., Parsippany, NJ) system.

View Article and Find Full Text PDF

Narrow inferior-central septum-based pedicle: A safe technique to improve aesthetic outcomes in breast reduction.

J Plast Reconstr Aesthet Surg

October 2023

Chair of Plastic Surgery, Department of Surgical Sciences, School of Medicine and Surgery, Tor Vergata University of Rome, Italy.

Background: Inferior-central pedicle has some aesthetic drawbacks, including hypertrophic scar along the inframammary fold (IMF), squaring of the breast contours, and propensity to develop long-term 'bottoming-out.' This study aimed to verify if the narrow inferior-central (NIC) septum-based pedicle can allow the surgeon to improve aesthetic outcomes compared with the traditional inferior-central pedicle approach.

Methods: Forty breasts underwent NIC-based breast reduction (group A), and 37 underwent traditional inferior-central pedicles (group B).

View Article and Find Full Text PDF

Breast Morphological Changes after Transaxillary Dual-Plane Augmentation with Smooth Round Implants: A Prospective Study.

Aesthetic Plast Surg

June 2023

Department of Aesthetic and Reconstructive Breast Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No.33 Badachu Road, Shijingshan, Beijing, 100144, China.

Background: Breast augmentation is the most performed cosmetic surgery in the world. Although smooth round implants are widely used, the trend in breast morphology change after dual-plane augmentation with such implants remains unclear. In this study, we analyzed the issue with the support of 3D scanning technology, which may help provide an objective basis for the evaluation of postoperative outcomes and the determination of follow-up time points.

View Article and Find Full Text PDF

Introduction: In patients with short nipple to inframammary fold (N-IMF) distance, as in tuberous breast, the cohesivity and gel distribution of shaped implants work as a controlled tissue expander, progressively adapting the tissues to the implant's shape. This phenomenon translates into a gradual increase of the N-IMF distance over time, but the true extent to which this occurs has not been quantified to date. This study aims to quantify the postoperative variation of the N-IMF distance in tuberous breast treated with shaped cohesive silicone breast implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!