[Validity of three methods for inmuno-diagnostic of neurocysticercosis: systematic review of the literature with meta-analysis 1960-2014].

Rev Chilena Infectol

Grupo de investigación Salud y Sostenibilidad, Escuela de Microbiología, Universidad de Antioquia, Medellín, Colombia.

Published: February 2017

Introduction: The screening of neurocysticercosis is complex and immunological methods have varying validity.

Objective: To evaluate the validity of ELISA for antigen and antibody, and EITB for antibody in the screening of neurocysticercosis.

Methods: Meta-analysis of diagnostic tests with an ex-ante protocol implemented in five databases with 15 search strategies, ensuring reproducibility in the selection and extraction of information. Sensitivity, specificity, likelihood ratios (LR), diagnostic odds ratio and ROC curve were estimated in MetaDiSc, and predictive values, and Youden index were estimated in Epidat.

Results: EITB presented sensitivity of 85.7% (95% CI 83.5-87.7), specificity 93.9% (95% CI = 92.7-95.0), PLR 19.6 (95% CI = 8,6-44.6), NLR 0.16 (95% CI = 0.12-0.21), OR diagnostic 136.2 (95% CI = 54.7-342.6) and area under the curve 0.926. In ELISA for antibody sensitivity was 87.5% (95% CI = 86.1-88.8), specificity 92.2% (95% CI = 91.4-93.0), PLR 11.3 (95% CI = 8.45-15.11), NLR 0.15 (95% CI = 0.13-0.18), diagnostic OR 87.4 (95% CI = 60.1-127.1) and area under the curve 0.950. ELISA for antigen showed low diagnostic validity. No differences were found in these parameters by sample, antigen or antibody type.

Conclusion: ELISA for antibodies and EITB have a similar diagnostic value, detection of serum and CSF showed a similar validity.

Download full-text PDF

Source
http://dx.doi.org/10.4067/S0716-10182017000100005DOI Listing

Publication Analysis

Top Keywords

95%
10
elisa antigen
8
antigen antibody
8
area curve
8
diagnostic
6
[validity three
4
three methods
4
methods inmuno-diagnostic
4
inmuno-diagnostic neurocysticercosis
4
neurocysticercosis systematic
4

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!