Rapid and accurate bacterial detection methods are needed for clinical diagnostic, water, and food testing applications. The wide diversity of bacterial nucleases provides a rich source of enzymes that could be exploited as signal amplifying biomarkers to enable rapid, selective detection of bacterial species. With the exception of the use of micrococcal nuclease activity to detect Staphylococcus aureus, rapid methods that detect bacterial pathogens via their nuclease activities have not been developed. Here, we identify endonuclease I as a robust biomarker for E. coli and develop a rapid ultrasensitive assay that detects its activity. Comparison of nuclease activities of wild-type and nuclease-knockout E. coli clones revealed that endonuclease I is the predominant DNase in E. coli lysates. Endonuclease I is detectable by immunoblot and activity assays in uropathogenic E. coli strains. A rapid assay that detects endonuclease I activity in patient urine with an oligonucleotide probe exhibited substantially higher sensitivity for urinary tract infections than that reported for rapid urinalysis methods. The 3 hr turnaround time is much shorter than that of culture-based methods, thereby providing a means for expedited administration of appropriate antimicrobial therapy. We suggest this approach could address various unmet needs for rapid detection of E. coli.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5474879 | PMC |
http://dx.doi.org/10.1016/j.ymthe.2017.03.015 | DOI Listing |
Environ Sci Pollut Res Int
January 2025
Center for Environmental Sustainability and Water Security (IPASA), Research Institute for Sustainable Environment (RISE), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
In the Johor River Basin, a comprehensive analysis was conducted on 24 water environmental parameters across 33 sampling sites over 3 years, encompassing both dry and wet seasons. A total of 396 water samples were collected and analyzed to calculate the Water Quality Index (WQI). To further assess water quality and pinpoint potential pollution sources, multivariate techniques such as principal component analysis (PCA) and cluster analysis (CA), alongside spatial analysis using inverse distance weighted (IDW) interpolation, were employed.
View Article and Find Full Text PDFWorld J Pediatr
January 2025
The First Hospital of Peking University, Beijing, China.
Background: Glucose transporter 1 deficiency syndrome (Glut1DS) was initially reported by De Vivo and colleagues in 1991. This disease arises from mutations in the SLC2A1 and presents with a broad clinical spectrum. It is a treatable neuro-metabolic condition, where prompt diagnosis and initiation of ketogenic dietary therapy can markedly enhance the prognosis.
View Article and Find Full Text PDFMethods Mol Biol
January 2025
Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey.
Next-Generation Sequencing (NGS), also known as high-throughput sequencing technologies, has enabled rapid and efficient sequencing of large amounts of DNA and RNA. These technologies have revolutionized the field of genomics, transcriptomics, and proteomics and have been widely used in cancer research, leading to advances in clinical diagnosis and treatment. Improvements in the NGS technologies enabled millions of fragments to be sequenced simultaneously in a time- and cost-effective manner and resulted in large amount of genomic data which require efficient analysis methods.
View Article and Find Full Text PDFAnal Methods
January 2025
Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (Ministry of Education), School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China.
In this work, a hydrophilic Eu-based ratiometric fluorescent nanosensor (PAAC-Eu) was developed for Cu ion detection in aqueous solutions and imaging in living cells. The sensor was prepared a simple one-step reaction at room temperature, leveraging the synergistic coordination of commercially accessible polyacrylic acid (PAA) and coumarin-3-carboxylic acid (CCAH) with Eu ions. PAAC-Eu was easy to disperse in aqueous media and exhibited two characteristic emission bands at 406 nm and 618 nm, respectively, upon excitation at 350 nm.
View Article and Find Full Text PDFAm J Manag Care
December 2024
Center for Healthcare Economics and Policy, FTI Consulting, 350 S Grande Ave, Los Angeles, CA 90071. Email:
Objective: To examine the relationship between adoption of direct oral anticoagulants (DOACs) and health and cost outcomes for patients with nonvalvular atrial fibrillation.
Study Design: Real-world cohort study.
Methods: US adults who newly initiated treatment for nonvalvular atrial fibrillation were identified from claims data.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!