A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Osseointegration improves bone-implant interface of pedicle screws in the growing spine: a biomechanical and histological study using an in vivo immature porcine model. | LitMetric

Purpose: Implant failure is a frequent complication in corrective surgery for early onset scoliosis, since considerable forces are acting on small and fragile vertebrae. Osseointegration showing biomechanical and histological improvement in bone-implant interface (BII) after dental implant placement has been well investigated. However, there are no studies regarding osseointegration in immature vertebral bone. The purpose was to evaluate the timecourse of biomechanical and histological changes at BII after pedicle screw placement using in vivo immature porcine model.

Methods: Ten immature porcine were instrumented with titanium pedicle screws in the thoracic spine. After a 0-, 2-, 4-, and 6-month survival periods, the spines were harvested at the age of 12 months. Histological evaluation of BII was conducted by bone volume/tissue volume (BV/TV) and bone surface/implant surface (BS/IS) measurements. Bone mineral density (BMD) measurement and biomechanical testing of BII were done.

Results: Contact surface and bone volume around the screw threads were significantly increased over the time. BV/TV and BS/IS were improved with statistically significant differences between 0- and ≥4-month (p ≤ 0.001) periods. BMD in all subjects was determined to be the same (p ≥ 0.350). Pullout strength was also increased over time with significant differences between 0- and ≥2-month (p ≤ 0.011) periods.

Conclusion: Improved stability at BII caused by osseointegration was confirmed by in vivo immature porcine model. A two-stage operation is proposed based on the osseointegration theory, in which an implant is installed in advance in the vertebrae at the first stage and deformity correction surgery is performed after sufficient stability is obtained by osseointegration at a later stage.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-017-5062-2DOI Listing

Publication Analysis

Top Keywords

immature porcine
16
biomechanical histological
12
vivo immature
12
bone-implant interface
8
pedicle screws
8
porcine model
8
increased time
8
osseointegration
6
immature
5
bii
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!