Absorbable Implant to Treat Nasal Valve Collapse.

Facial Plast Surg

Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilian University of Munich, Munich, Germany.

Published: April 2017

 To evaluate the safety and effectiveness of an absorbable implant for lateral cartilage support in subjects with nasal valve collapse (NVC) with 12 months follow-up.  Thirty subjects with Nasal Obstruction Symptom Evaluation (NOSE) score ≥ 55 and isolated NVC were treated; 14 cases were performed in an operating suite under general anesthesia and 16 cases were performed in a clinic-based setting under local anesthesia. The implant, a polylactic acid copolymer, was placed with a delivery tool within the nasal wall to provide lateral cartilage support. Subjects were followed up through 12 months postprocedure.  Fifty-six implants were placed in 30 subjects. The mean preoperative NOSE score was 76.7 ± 14.8, with a range of 55 to 100. At 12 months, the mean score was 35.2 ± 29.2, reflecting an average within-patient reduction of -40.9 ± 31.2 points. The majority (76%) of the subjects were responders defined as having at least one NOSE class improvement or a NOSE score reduction of at least 20%. There were no adverse changes in cosmetic appearance at 12 months postprocedure. Three implants in three subjects required retrieval within 30 days postprocedure and resulted in no clinical sequelae.  This study demonstrates safety and effectiveness of an absorbable implant for lateral cartilage support in subjects with NVC at 12 months postprocedure.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0037-1598655DOI Listing

Publication Analysis

Top Keywords

absorbable implant
12
lateral cartilage
12
cartilage support
12
support subjects
12
months postprocedure
12
nasal valve
8
valve collapse
8
safety effectiveness
8
effectiveness absorbable
8
implant lateral
8

Similar Publications

Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.

Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.

Study Design: Systematic review; Level of evidence, 5.

View Article and Find Full Text PDF

Comparative Analysis of Gelatin/Polylactic Acid and Commercial PLA Membranes for Guided Bone Regeneration: A Randomized Clinical Trial.

Med Sci Monit

January 2025

Department of Oral Implantology, The Affiliated Stomatology Hospital, Jiangxi Medical College, Nanchang University, Jiangxi Province Key Laboratory of Oral Biomedicine, Jiangxi Province Clinical Research Center for Oral Disease, Nanchang, Jiangxi, China.

BACKGROUND This study included 32 patients with single missing teeth and alveolar bone defects and aimed to compare outcomes from guided bone regeneration with a gelatin/polylactic acid (GT/PLA) barrier membrane and a Guidor® bioresorbable matrix barrier dental membrane. MATERIAL AND METHODS A total of 32 participants were recruited in the clinical study, with single missing teeth and alveolar bone defects, requiring guided bone regeneration (32 missing teeth in total). They were randomly divided into the GT/PLA membrane group (experimental) and Guidor® membrane group (control) by the envelope method (n=16).

View Article and Find Full Text PDF

Backgroud: Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.

Methods: A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024.

View Article and Find Full Text PDF

Background: Adhesion formation poses a significant challenge for both patients and hand surgeons following tendon repair. One common strategy to prevent adhesion formation is the use of physical barriers. This study aimed to compare the outcomes of extensor tendon repair with and without the application of the OrthoWrap bioresorbable Sheet, specifically in terms of adhesion prevention.

View Article and Find Full Text PDF

Background: The Orsiro and Genoss DES stents are biodegradable polymer drug-eluting stents (DESs) with ultrathin struts.

Objective: To investigate the safety and efficacy of these two ultrathin DESs in real-world practice.

Methods: From a single-center prospective registry, we included 751 and 931 patients treated with the Genoss DES and Orsiro stents, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!