An All-Stretchable-Component Sodium-Ion Full Battery.

Adv Mater

Materials Science and Engineering Program and Department of Mechanical Engineering, The University of Texas at Austin, TX, 78712, USA.

Published: June 2017

Stretchable energy-storage devices receive considerable attention due to their promising applications in future wearable technologies. However, they currently suffer from many problems, including low utility of active materials, limited multidirectional stretchability, and poor stability under stretched conditions. In addition, most proposed designs use one or more rigid components that fail to meet the stretchability requirement for the entire device. Here, an all-stretchable-component sodium-ion full battery based on graphene-modified poly(dimethylsiloxane) sponge electrodes and an elastic gel membrane is developed for the first time. The battery exhibits reasonable electrochemical performance and robust mechanical deformability; its electrochemical characteristics can be well-maintained under many different stretched conditions and after hundreds of stretching-release cycles. This novel design integrating all stretchable components provides a pathway toward the next generation of wearable energy devices in modern electronics.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adma.201700898DOI Listing

Publication Analysis

Top Keywords

all-stretchable-component sodium-ion
8
sodium-ion full
8
full battery
8
stretched conditions
8
battery stretchable
4
stretchable energy-storage
4
energy-storage devices
4
devices receive
4
receive considerable
4
considerable attention
4

Similar Publications

An All-Stretchable-Component Sodium-Ion Full Battery.

Adv Mater

June 2017

Materials Science and Engineering Program and Department of Mechanical Engineering, The University of Texas at Austin, TX, 78712, USA.

Stretchable energy-storage devices receive considerable attention due to their promising applications in future wearable technologies. However, they currently suffer from many problems, including low utility of active materials, limited multidirectional stretchability, and poor stability under stretched conditions. In addition, most proposed designs use one or more rigid components that fail to meet the stretchability requirement for the entire device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!