Objective: A number of case reports have demonstrated FDG uptake around mesh prostheses after hernia repair surgery. This study characterizes FDG PET-CT findings after hernia repair with synthetic mesh in a series of cancer patients.

Materials And Methods: FDG PET-CT studies were reviewed for increased FDG uptake consistent with CT appearances of post-surgical hernia repair in cancer patients. The findings were correlated with clinical data and follow-up studies.

Results: 53 PET-CT studies in 22 patients (18 males, 31-79 years) were identified. Surgery for repair of inguinal (n = 14), ventral (n = 5) or umbilical (n = 3) hernia was performed, 4-204 months prior to PET-CT. FDG avidity was focal or linear in the region of the anterior abdominal or pelvic wall (mean SUV max 4.0 ± 2.3). Corresponding nonspecific CT findings included soft tissue thickening (n = 18), fat infiltration (n = 20) and fluid collection (n = 19) in the region of the omentum, adjacent to or in the inner abdominal or pelvic wall at the surgical site. Linear hyper-dense structures (n = 9) or metallic clips (n = 8) seen on CT suggested benign postoperative changes. In 10/12 (83.3%) patients with repeat PET-CT, FDG uptake remained unchanged, one showed more diffuse uptake and another showed reduced uptake on follow-up. There was neither significant change in CT appearance at the surgical site in these 12 patients, nor in 3 additional patients with only CT follow-up. Another 3 patients had previous CT demonstrating hernia at the same location.

Conclusion: With increasing use of synthetic mesh, awareness of variations in FDG PET-CT appearance is important to avoid false interpretation in cancer patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10029-017-1596-9DOI Listing

Publication Analysis

Top Keywords

hernia repair
16
fdg uptake
12
fdg pet-ct
12
postoperative changes
8
synthetic mesh
8
pet-ct studies
8
cancer patients
8
pet-ct fdg
8
abdominal pelvic
8
pelvic wall
8

Similar Publications

Purpose: To determine the prevalence of scoliosis in patients who have undergone surgical repair of CDH and attempt to assess the aetiology of scoliosis in affected cases.

Methods: A prospectively collected database of patients with CDH treated in a single centre between 1997 and 2023 was reviewed. Cases with adequate records who continued to reside locally having survived beyond age 2 and > 2 years following CDH repair were included.

View Article and Find Full Text PDF

Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model.

Surg Endosc

January 2025

Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, China.

Background: Self-gripping mesh, made of monofilament polypropylene and covered by a layer of polylactic acid micro-hooks, is applied in ventral hernia repair, whereas cytological change and collagen expression around the mesh are rarely reported. The objective of this research was to compare inflammatory response and collagen proliferation between self-gripping and polypropylene mesh in rat model of incisional hernia.

Methods: Forty-five rats were randomly divided into unrepaired (UR) group, polypropylene (PP) mesh group, and self-gripping (SG) mesh group and euthanized at 1, 2 and 4 weeks postoperatively.

View Article and Find Full Text PDF

Concerns exist regarding increased trauma activation fees at the expense of vulnerable patients. In contrast, elective open inguinal hernia repair (E-OIHR) has remained relatively fixed in terms of technique. This study aimed to examine health care costs for E-OIHR and trauma patients, hypothesizing trauma cost would increase from 2010 to 2018, while E-OIHR cost would remain unchanged.

View Article and Find Full Text PDF

Rare but important gastrointestinal complications after laparoscopic inguinal hernia repair: a single-center experience.

Sci Rep

January 2025

Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, No. 99, Longcheng Street, Xiaodian District, Taiyuan, 030032, Shanxi Province, China.

Transabdominal preperitoneal patch plasty (TAPP) versus total extraperitoneal patch plasty (TEP) are surgical techniques commonly used to treat inguinal hernia. However, studies indicate that both procedures may lead to significant complications, particularly gastrointestinal complications, some of which can be life-threatening. We statistically analyzed the complications caused by adult inguinal hernia patients admitted from 2018 to 2022.

View Article and Find Full Text PDF

Introduction: The classic open ventral hernia repair provides excellent results in recurrences. However, wound complications are the Achilles heel for a good overall clinical outcome. Laparoscopic surgery is in general associated with less pain, better esthetic results, faster recovery, and lower incidence of wound complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!