A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single Molecule Catch and Release: Potential-Dependent Plasmid DNA Adsorption along Chemically Graded Electrode Surfaces. | LitMetric

Single molecule detection methods were employed to study the potential dependent adsorption and desorption of dye labeled plasmid DNA along chemical gradients prepared on indium tin oxide (ITO) electrodes. Gradients were formed over silica-base-layer-coated ITO surfaces by exposing them in a directional fashion to aminopropyltrimethoxysilane from the vapor phase. Sessile drop water contact angle measurements, spectroscopic ellipsometry, and X-ray photoelectron spectroscopy were used to verify that a gradient was formed and to characterize its wettability, thickness, and composition as a function of position. The gradient-coated ITO electrode served as both the working electrode and a window into the electrochemical cell used to manipulate DNA adsorption. For single molecule studies, the electrochemical cell was filled with buffer solution containing YOYO-1-labeled plasmid DNA. Fluorescence videos acquired along the gradients depicted clear position-, potential-, and pH-dependent variations in DNA adsorption and desorption. The results demonstrate that DNA adsorption was largely independent of applied potential and irreversible at high amine coverage (i.e., multilayers), under pH ∼ 6 buffer. DNA adsorption became more reversible as the amine coverage decreased and the solution pH increased. Potential dependent control over DNA adsorption and desorption was best achieved at monolayer-to-submonolayer aminosilane coverage under pH ∼ 8 buffer. The knowledge gained in these studies will aid in the development of electrochemical methods for the capture and release of DNA and other polyelectrolytes at electrode surfaces.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.7b00044DOI Listing

Publication Analysis

Top Keywords

dna adsorption
24
single molecule
12
plasmid dna
12
adsorption desorption
12
dna
9
electrode surfaces
8
potential dependent
8
electrochemical cell
8
amine coverage
8
∼ buffer
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!