A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Radiation loading problems in petrous bone tomography. Experimental research using film dosimetry on the Alderson phantom]. | LitMetric

[Radiation loading problems in petrous bone tomography. Experimental research using film dosimetry on the Alderson phantom].

Rofo

Radiologische Abteilung des Caritas-Krankenhauses Bad Mergentheim.

Published: June 1988

Using film dosimetry and an Alderson skull phantom, the iso-dose distribution during tomography of the petrous bone was investigated. We were particularly concerned with the radiation dose to the lens of the eye, the critical organ in the skull, and to the inner ear, using different types of examination and various positions of the skull. The choice of suitable film material and standardisation against TLD measurements is crucial for the accuracy of film dosimetry, allowing for correction of film blackening in relation to varying energies. Tomography of the petrous bone in the prone position produced a reduction in radiation dose to the eye to only 1 to 4% of the dose incident on the occiput. In this way, and using high definition screen and grinds, it is possible to obtain optimal tomographic images despite drastic reduction of the scattered radiation to the eye. Radiation dose to the inner ear is greatly below any significant somatic does, irrespective of projection or technique. Special measures to reduce radiation to the inner ear are neither effective nor sensible.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2008-1048275DOI Listing

Publication Analysis

Top Keywords

petrous bone
12
film dosimetry
12
radiation dose
12
inner ear
12
dosimetry alderson
8
tomography petrous
8
film
5
radiation
5
[radiation loading
4
loading problems
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!