Background: Previous studies investigated the overall mechanical strength of the vertebral body; however, limited information is available on the biomechanical properties of different regions within the vertebral endplate and cancellous bone. In addition, the correlation between mechanical strength and various density measurements has not been studied yet.

Methods: Thoracic (T10) vertebrae were harvested from fifteen human cadaveric spines (average age: 77 years old). Twelve cylindrical cores of 7.2 mm (diameter) by 3.2 mm (height) were prepared from each vertebral body. Shear was produced using a stainless steel tubular blade and measured with a load cell from a mechanical testing machine. Optical and bulk densities were calculated before mechanical testing. Apparent, material, and ash densities were measured after testing.

Results: Material density and shear strength increased from anterior to lateral regions of both endplate and cancellous bone. Endplate shear strength was significantly lower in the anterior (0.52 ± 0.08 MPa) than in the lateral region (2.72 ± 0.59 MPa) (p=0.017). Trabecular bone maximum load carrying capacity was 5 times higher in the lateral (12 ± 2.74 N) (p=0.09) and 4.5 times higher in the central (10 ± 2.24 N) (p=0.2) than in the anterior (2 ± 0.60 N) regions. Mechanical strength positively correlated with ash density, and even moreso with material density.

Conclusion: Shear strength was the lowest at the anterior region and highest at the lateral region for both endplate and cancellous bone. Material density had the best correlation with mechanical strength. Newer spinal implants could optimize the loading in the lateral aspects of both endplate and cancellous bone to reduce the likelihood of screw loosening and the subsidence of disc replacement devices. This study was reviewed by the SUNY Downstate Medical Center IRB Committee; IRB#: 533603-2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375017PMC
http://dx.doi.org/10.14444/4007DOI Listing

Publication Analysis

Top Keywords

shear strength
16
mechanical strength
16
endplate cancellous
16
cancellous bone
16
strength
8
strength density
8
vertebral endplate
8
trabecular bone
8
vertebral body
8
correlation mechanical
8

Similar Publications

Introduction: Biofilms may show varying adherence strengths to dentine. This study quantified the shear force required for the detachment of multispecies biofilm from the dentine using fluid dynamic gauging (FDG) and computation fluid dynamics (CFD). To date this force has not been quantified.

View Article and Find Full Text PDF

Simultaneous Toughening and Strengthening of Ductile Polymer by Rigid Polymeric Fillers: The Role of Interfacial Entanglement.

Macromol Rapid Commun

January 2025

Department of Materials Science and Engineering, National University of Singapore (NUS), 9 Engineering Drive 1, Singapore, 117575, Singapore.

The modification of thermoplastic polymers is frequently impeded by the inherent contradiction between their toughness and strength. In this study, an effective strategy to significantly improve the mechanical properties of ductile polymers by simply adding a complimentary rigid polymer is introduced. This work uses a semi-crystalline polymer aliphatic polyketone (POK) as the matrix material and a small quantity of polymethyl methacrylate (PMMA) as the rigid polymer, through establishing molecular chain entanglements at the interface to produce POK/PMMA blends with exceptional mechanical property.

View Article and Find Full Text PDF

The adhesion mechanism of mucoadhesive tablets with dissimilar chain flexibility on viscoelastic hydrogels.

Mater Today Bio

February 2025

Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., H-1111, Budapest, Hungary.

Mucosal membranes with strong variability in their viscoelastic properties line numerous organs and are often targeted by mucoadhesive formulations, e.g., highly swellable hydroxypropylmethylcellulose (HPMC) and slightly cross-linked poly(acrylic acid) (PAA) tablets.

View Article and Find Full Text PDF

Outcome of Er, Cr:YSGG laser and antioxidant pretreatments on bonding quality to caries-induced dentin.

BMC Oral Health

January 2025

Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Future University, Cairo, Egypt.

Background: This study aimed to assess the influence of different pretreatment protocols and antioxidants application on the shear bond strength (SBS) of universal adhesive to sound (SoD) and caries-induced dentin (CID).

Methods: One hundred and twenty posterior teeth had their occlusal enamel removed, then the specimens were divided into two main groups according to dentin substrates; SoD and CID, three subgroups according to pretreatments protocols control (no pretreatment), NaOCl-treated, and Er, Cr:YSGG-treated and two divisions according to antioxidant application (with and without sodium ascorbate (SA) application). All-Bond Universal (ABU) universal adhesives was applied in self-etch (SE) mode then resin composite discs were built.

View Article and Find Full Text PDF

Temperature dynamics and mechanical properties analysis of carbon fiber epoxy composites radiated by nuclear explosion simulated light source.

Sci Rep

January 2025

Engineering Research Center of Flexible Radiation Protection Technology, Universities of Shaanxi Province, Xi'an Polytechnic University, Xi'an, 710048, Shaanxi, China.

The impact of light radiation, a predominant energy release mechanism in nuclear explosions, on material properties is of critical importance. This investigation employed an artificial light source to replicate the effects of nuclear explosion radiation and utilized a physical information neural network (PINN) to examine the temperature evolution and corresponding changes in the mechanical properties of carbon fiber/epoxy composites (CFEC). A light source simulating nuclear explosion's light radiation was built to irradiate the CFEC, then measure the reflection spectrum and temperature of samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!