From the Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, Ontario, Canada (D.J., S.H., C.R., J.B., S.C., G.W., R.S.B.B., B.J.W.C.); Division of Nuclear Medicine, Department of Medicine, University of Ottawa, Ontario, Canada (M.G., L.S.Z., S.G., E.L.); and Division of Nuclear Medicine, Medical Imaging Department, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada (D.J.).

Published: April 2017

Background: The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography, labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection.

Methods And Results: A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%-91%) and pooled specificity was 94% (95% CI, 88%-98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%.

Conclusions: Both F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for F-FDG PET-CT but limited data for LS. When available,F-FDG PET-CT may be preferred.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.116.005772DOI Listing

Publication Analysis

Top Keywords

f-fdg pet-ct
16
diagnosis cied
12
cied infection
12
positron emission
8
emission tomography
8
computed tomography
8
cardiac implantable
8
implantable electronic
8
systematic review
8
citrate scintigraphy
8

Similar Publications

A 61-year-old male presented with hematemesis and melena. Biopsy and immunohistochemistry confirmed mucosa-associated lymphoid tissue (MALT) lymphoma in the posterior wall of the gastric antrum, prompting further evaluation with F-fluorodeoxyglucose (F-FDG) positron emission tomography/computed tomography (PET/CT). In addition to elevated uptake in the gastric antrum, F-FDG PET/CT showed diffuse uptake in multiple bone marrow, initially suspected to indicate bone marrow involvement by lymphoma.

View Article and Find Full Text PDF

Primary cutaneous anaplastic large cell lymphoma (pcALCL) is a type of skin T-cell lymphoma with a favorable prognosis. Some patients may experience recurrence, but systemic involvement is rare. Some studies suggest that systemic progression is associated with poor prognosis.

View Article and Find Full Text PDF

Background And Objectives: This study aims to evaluate the correlation between Tumor-Infiltrating Lymphocyte (TIL) levels and Fluorine-18 fluorodeoxyglucose (F-FDG) metabolic parameters, including spleen and bone marrow FDG uptake and tumor heterogeneity in non-luminal breast cancers (NLBC), and to elucidate their association with survival outcomes.

Methods: We retrospectively analyzed data from 100 females with stage 2-4 NLBC who underwent pretreatment F-FDG Positron emission tomography-computed tomography (PET/CT). TIL was scored based on Hematoxylin-Eosin-stained specimens and F-FDG PET metabolic parameters, including maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), metabolic tumor volume (MTV), total lesion glycolysis (TLG), liver, spleen, and bone marrow FDG uptake were calculated.

View Article and Find Full Text PDF

Background: Radiomics features extracted from baseline F-fluorodeoxyglucose positron emission tomography (F-FDG PET) scans have shown promising results in predicting the treatment response and outcome of diffuse large B-cell lymphoma (DLBCL) patients. This study aimed to assess the influence of lesion selection approaches and segmentation methods on the radiomics of DLBCL in terms of treatment response and prognosis prediction.

Methods: A total of 522 and 382 patients pathologically diagnosed with DLBCL were enrolled for complete regression and 2-year event-free survival prediction, respectively.

View Article and Find Full Text PDF

Objectives: To assess the prognostic value of Fluorine 18-labeled fluorodeoxyglucose [F]FDG, gallium 68-labeled fibroblast-activation protein inhibitor-04 [Ga]Ga-FAPI-04, C-acetate in hepatocellular carcinoma (HCC) and evaluate the potential usefulness and advantages of different combinations for accurate diagnosis.

Materials And Methods: Thirty-six patients with suspected hepatic masses were prospectively enrolled from May 2021 to September 2022 and underwent [F]FDG, [Ga]Ga-FAPI-04, and C-acetate PET/CT scans before surgery. PET/CT results and histopathologic examinations were independently interpreted by two radiologists and pathologists, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!