A 77-year-old male patient presented with a symptomatic, 66-mm pararenal aortic aneurysm. The patient was classified as unsuitable for open surgery due to significant comorbidities. Fenestrated or branched endografts were contraindicated due to the poor iliac access (6 mm diameter). A double Nellix with chimney endovascular aneurysm sealing (ChEVAS) technique was selected to exclude the pararenal aortic aneurysm and to preserve renal arteries and the superior mesenteric artery. Technical preplanning considered the ideal proximal landing zone to be close to the origin of the almost occluded celiac trunk and the distal common iliac arteries as the ideal distal landing zone. The total length of the aorta to cover was estimated as >180 mm, requiring 2 aortic EVAS systems, bilaterally overlapped. Technical success was achieved, and the patient was discharged on postoperative day 8 in good general condition. Successful aneurysm exclusion and target vessel patency without endoleak or stent-graft kinking or migration were confirmed at angio-computed tomography at 6 months.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1538574417702772DOI Listing

Publication Analysis

Top Keywords

pararenal aortic
12
aortic aneurysm
12
double nellix
8
nellix chimney
8
landing zone
8
aneurysm
5
chimney covered
4
covered stents
4
stents challenging
4
challenging treatment
4

Similar Publications

Objectives: This study aims to evaluate the technical and clinical outcomes of the E-nside stent graft for thoraco-abdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm (PAAA) endovascular treatment at our University Hospital Center.

Methods: We conducted a retrospective analysis of patients electively treated by inner branched EVAR (iBEVAR) between 05/2021 and 03/2023. Demographic, procedural, and clinical data were analyzed.

View Article and Find Full Text PDF

A 77-year-old woman underwent CT to evaluate haematemesis. The images showed that the third part of the duodenum flexed steeply on the right side of the aorta and ran caudally, without crossing anterior to the aorta. The duodenal-jejunal junction and jejunum were located on the patient's right side.

View Article and Find Full Text PDF

Background: Hostile aortic neck anatomy is associated with loss of proximal seal and increased late reinterventions. Although both EndoSuture aneurysm repair (ESAR) and fenestrated endovascular aortic repair (FEVAR) are commercially available options for treatment of short neck aneurysms, branch vessel patency is a potential tradeoff for improved seal with FEVAR owing to the incorporation of renovisceral vessels. This study compares the performance of ESAR vs FEVAR in hostile aortic necks.

View Article and Find Full Text PDF
Article Synopsis
  • * Data was collected from four European aortic centers between 2019 and 2023, focusing on patients with either ruptured or symptomatic aneurysms, looking at access complications, spinal cord issues, and mortality over a 30-day period, along with long-term outcomes like survival and need for interventions.
  • * Findings showed a 9% complication rate from access, with a 7% mortality rate within 30 days;
View Article and Find Full Text PDF

Objectives: In this multicentre retrospective observational study, we present the early outcomes of physician-modified fenestrated/inner-branched endovascular repair for pararenal and thoracoabdominal aortic aneurysms in patients at high risk for open surgical repair.

Methods: We comprehensively reviewed the clinical data and outcomes of consecutive patients treated with physician-modified fenestrated/inner-branched endovascular repair for pararenal or thoracoabdominal aortic aneurysms at 6 centres between December 2020 and December 2021. Primary end-points included technical success, in-hospital mortality rates, major adverse events.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!