A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safe Zone of Posterior Screw Insertion for Talar Neck Fractures on 3-Dimensional Reconstruction Model. | LitMetric

Safe Zone of Posterior Screw Insertion for Talar Neck Fractures on 3-Dimensional Reconstruction Model.

Orthop Surg

Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, China.

Published: February 2017

Objective: To investigate the optimal posterior screw placement and the geometry of safe zones for screw insertion in the talar neck.

Methods: Computed tomography data for 15 normal feet were imported into Mimics 10.01 software for 3-dimensional reconstruction; 4.0-mm-diameter screws were simulated from the lateral tubercle of the posterior process of the talus to the talar head. The range of screw paths trajectories and screw lengths at nine locations that did not breach the cortex of the talus were evaluated. In addition, the farthest (point a) and nearest point (point b) of the safe zone to the subtalar joint at each location, the anteversion angle (angle A), which is parallel to the sagittal plane, and the horizontal angle (angle B), which is perpendicular to the sagittal plane, were measured.

Results: The safe zone was mainly between the 30% location and the 60% location; the width of each safe zone was 13.6° ± 1.4°; the maximum height of each safe zone was 7.8° ± 1.2°. The height of the safe zone was lowest at the 30% location (4.5°) and highest at the 50% location (7.3°). The mixed safe zone of all tali was between the 50% location and the 60% location. When a screw was inserted at point a, the safe entry distance (screw length) ranged from 48.8 to 49.5 mm, and when inserted to point b, the distance ranged from 48.2 to 48.9 mm. And inserting a 48.7 mm screw, 5.6° laterally and 7.4° superiorly, from the lateral tubercle of the posterior process of the talus towards the talar head is safest.

Conclusion: The safe zone of posterior screw fixation have been defined applying to most talus, assuming the fractures are well reduced, this may strengthen the stability, shorten the operation time and reduce the incidence of surgical complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6584388PMC
http://dx.doi.org/10.1111/os.12303DOI Listing

Publication Analysis

Top Keywords

safe zone
32
posterior screw
12
safe
10
screw
9
zone posterior
8
screw insertion
8
insertion talar
8
3-dimensional reconstruction
8
lateral tubercle
8
tubercle posterior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!