A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anterior intercostal artery perforator flap in immediate breast reconstruction: Anatomical study and clinical application. | LitMetric

Background: Although the use of lateral intercostal artery perforator (ICAP) flaps for immediate breast reconstruction has been widely described, data on the use of the anterior ICAP (AICAP) flaps for this indication are limited. In this context, we describe the results of anatomical study and our clinical experience with AICAP flaps for breast reconstruction.

Methods: In this study, the location and characteristics of the AICAPs were dissected in 12 female adult formalin-preserved hemitrunks and two fresh-frozen cadavers. Fourteen patients (mean BMI 23) underwent partial breast resection for a quadrant breast cancer followed by breast reconstruction with an intercostal perforator flap. The mean resection size was 6 × 5 × 5.5 cm (range 3-8 × 3.5-7 × 4-8 cm).The main outcome measures were pre-operative and postradiotherapy health-related quality of life assessed with the BREAST-Q reconstruction survey.

Results: According to anatomical study, at least one perforator was found in each third of hemitrunks dissected. The mean of perforator size was in diameter 0.42 ± 0.05 mm and in length 3.1 ± 0.36 cm. In clinical outcomes, the mean of flap size was 16 × 5 × 3 cm (range 14-19 × 3-8 × 2-5 cm). The mean surgical time was 120 min (range 109-125 min). Only one partial flap failure was detected. No postoperative changes in breast size were observed, although soft tissue changes were observed in four patients after radiotherapy. The mean BREAST-Q scores changes were 0 in satisfaction with the breast, 5 in satisfaction with outcome, 0 in psychosocial well-being, 6.15 in sexual well being, and 34.69 in physical well-being.

Conclusions: Based on this anatomical and clinical study, we found AICAP flap has a consistent vascularization with good perforators. And moreover, it is suitable for partial breast reconstruction (quadrantectomy) and does not appear to negatively impact patient satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1002/micr.30171DOI Listing

Publication Analysis

Top Keywords

breast reconstruction
16
anatomical study
12
breast
9
intercostal artery
8
artery perforator
8
perforator flap
8
study clinical
8
flaps breast
8
aicap flaps
8
partial breast
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!