Pacemaker magnet application during surgery for patients who are pacemaker-dependent is often utilized to avoid perioperative inhibition from electromagnetic interference. We present a case during which such routine magnet use resulted in an unexpected response and discuss the limitations and nuances of this common practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.13084 | DOI Listing |
Eur Radiol
January 2025
Department of Radiology, Geneva University Hospitals, Geneva, Switzerland.
Objectives: Evaluating the impact of an AI-based automated cardiac MRI (CMR) planning software on procedure errors and scan times compared to manual planning alone.
Material And Methods: Consecutive patients undergoing non-stress CMR were prospectively enrolled at a single center (August 2023-February 2024) and randomized into manual, or automated scan execution using prototype software. Patients with pacemakers, targeted indications, or inability to consent were excluded.
Eur Heart J Case Rep
January 2025
Cardiology Department, Loyola University Medical Center, 2160 S 1st Ave, Maywood, IL 60153-3328, USA.
Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.
Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.
Neth Heart J
February 2025
Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Centre, Maastricht, The Netherlands.
The European Society of Cardiology (ESC) has updated its guidelines on cardiac pacing and cardiac resynchronisation. As the majority are class II recommendations (61%) and based on expert opinion (59%), a critical appraisal for the Dutch situation was warranted. A working group has been established, consisting of specialists in cardiology, cardiothoracic surgery, geriatrics, allied professionals in cardiac pacing, and patient organisations with support from the Knowledge Institute of the Dutch Association of Medical Specialists.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Department of Cardiology, Boston Children's Hospital and Department of Pediatrics, Harvard Medical School, Boston, MA, 02115, USA.
The number of children with cardiac implantable electronic devices (CIEDs) is increasing at a time of rapid growth in cardiac magnetic resonance (MR) and cardiac computed tomography (CT) utilization. The presence of CIEDs poses challenges with respect to imaging safety and quality. A thoughtful approach to cardiovascular imaging in patients with CIEDs begins with an awareness of the clinical indications to determine the most appropriate imaging modality.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Cardiac Electrophysiology, National Medical Center 'November 20th', ISSSTE, Av. Felix Cuevas #540, Col. Del Valle Del. Benito Juarez, C.P. 03100 Mexico City, Mexico.
Background: The 'univentricular' heart encompasses a variety of congenital cardiac defects characterized by a single functional ventricle and an underdeveloped ventricular chamber. Surgical intervention, typically in infancy or childhood, aims to regulate pulmonary blood flow volume. In adulthood, untreated patients may experience limitations in physical activity and elevated morbidity due to persistent cyanosis and arrhythmias, notably after the Fontan procedure.