SLIDE: automatic spine level identification system using a deep convolutional neural network.

Int J Comput Assist Radiol Surg

Department of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver, BC, V6T 1Z4, Canada.

Published: July 2017

Purpose: Percutaneous spinal needle insertion procedures often require proper identification of the vertebral level to effectively and safely deliver analgesic agents. The current clinical method involves "blind" identification of the vertebral level through manual palpation of the spine, which has only 30% reported accuracy. Therefore, there is a need for better anatomical identification prior to needle insertion.

Methods: A real-time system was developed to identify the vertebral level from a sequence of ultrasound images, following a clinical imaging protocol. The system uses a deep convolutional neural network (CNN) to classify transverse images of the lower spine. Several existing CNN architectures were implemented, utilizing transfer learning, and compared for adequacy in a real-time system. In the system, the CNN output is processed, using a novel state machine, to automatically identify vertebral levels as the transducer moves up the spine. Additionally, a graphical display was developed and integrated within 3D Slicer. Finally, an augmented reality display, projecting the level onto the patient's back, was also designed. A small feasibility study [Formula: see text] evaluated performance.

Results: The proposed CNN successfully discriminates ultrasound images of the sacrum, intervertebral gaps, and vertebral bones, achieving 88% 20-fold cross-validation accuracy. Seventeen of 20 test ultrasound scans had successful identification of all vertebral levels, processed at real-time speed (40 frames/s).

Conclusion: A machine learning system is presented that successfully identifies lumbar vertebral levels. The small study on human subjects demonstrated real-time performance. A projection-based augmented reality display was used to show the vertebral level directly on the subject adjacent to the puncture site.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-017-1575-8DOI Listing

Publication Analysis

Top Keywords

vertebral level
16
identification vertebral
12
vertebral levels
12
system deep
8
deep convolutional
8
convolutional neural
8
neural network
8
vertebral
8
real-time system
8
identify vertebral
8

Similar Publications

Wearable communication technologies necessitate antenna designs that harmonize ergonomic compatibility, reliable performance, and minimal interaction with human tissues. However, high specific absorption rate (SAR) levels, limited radiation efficiency, and challenges in integration with flexible materials have significantly constrained widespread deployment. To address these limitations, this manuscript introduces a novel wearable cavity-backed substrate-integrated waveguide (SIW) antenna augmented with artificial magnetic conductor (AMC) structures.

View Article and Find Full Text PDF

Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.

View Article and Find Full Text PDF

: Multilevel cervical spondylotic myelopathy (MCSM) presents complex challenges for surgical management, particularly in patients with kyphosis or significant anterior pathology. This study aimed to assess the long-term efficacy of modified expansive open-door laminoplasty (MEOLP) combined with short-level anterior cervical fusion (ACF) in providing decompression, preserving alignment, and maintaining range of motion (ROM) over a nine-year follow-up. : A retrospective analysis was conducted on 124 MCSM patients treated with MEOLP combined with ACF between 2011 and 2015.

View Article and Find Full Text PDF

Optimizing Scan Range in Computed Tomography of Kidneys, Ureters, and Bladder: A Retrospective Study on Reducing Overscanning.

Medicina (Kaunas)

November 2024

Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, P.O. Box 145111, Riyadh 4545, Saudi Arabia.

: Computed tomography of the kidneys, ureters, and bladder (CT KUB) is essential for evaluating urinary stones but also exposes patients to significant radiation. The scanning field should be minimized to only the necessary area to limit this radiation exposure. This study aims to assess the extent of CT KUB overscanning in renal colic procedures and identify the appropriate vertebral level for starting CT KUB scans.

View Article and Find Full Text PDF

: The main aim of this study was to evaluate the impact of cervical pain on the quality of life of patients with multiple sclerosis in comparison with a group of healthy people (without diseases of the Central Nervous System). : Data were collected at the Specialist Hospital St. Łukasz in Końskie (Poland) in the period from November 2023 to August 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!