Laboratory Monitoring of Non-Vitamin K Antagonist Oral Anticoagulant Use in Patients With Atrial Fibrillation: A Review.

JAMA Cardiol

Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada3Thrombosis and Atherosclerosis Research Institute, Hamilton, Ontario, Canada4Hamilton Health Sciences, Hamilton, Ontario, Canada6Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, Ontario, Canada.

Published: May 2017

Importance: The non-vitamin K antagonist oral anticoagulants (NOACs) apixaban, dabigatran, edoxaban, and rivaroxaban are administered in fixed doses without anticoagulant monitoring. Randomized trials show that unmonitored NOAC therapy is at least as effective as and safer than dose-adjusted warfarin for stroke prevention in patients with nonvalvular atrial fibrillation. Subgroup analyses indicate that plasma drug levels or anticoagulant activity of the NOACs predict stroke and bleeding. This review examines the historical basis for anticoagulant monitoring, discusses methods to measure and interpret drug levels, and critically assesses the role of routine laboratory monitoring in the management of NOAC therapy.

Observations: The predictable anticoagulant response of NOACs has provided the pharmacological basis for their administration in fixed doses without routine coagulation monitoring. Although it is possible to accurately measure NOAC drug levels, within-patient variability complicates interpretation of these results. Furthermore, patient characteristics, such as age and renal function, confound the association between NOAC drug levels and clinical outcomes. Information is lacking on the optimal drug level in particular patient groups (eg, elderly, the renally impaired, and those with high bleeding risk), the appropriate dose adjustment to achieve expected levels, and whether routine laboratory monitoring and dose adjustment will improve clinical outcomes. A benefit of a management strategy that incorporates routine therapeutic drug monitoring and dose adjustment over current standard-of-care metrics without such monitoring remains unproven.

Conclusions And Relevance: Robust evidence from patients with atrial fibrillation randomized to NOACs or warfarin demonstrates that unmonitored NOAC therapy is at least as effective and safe as monitored warfarin, with lower rates of intracranial hemorrhage and reduced mortality. Further research is required to determine whether routine laboratory monitoring might provide a net benefit for patients. Until such data are available, clinicians should continue to prescribe NOACs in fixed doses without routine monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1001/jamacardio.2017.0364DOI Listing

Publication Analysis

Top Keywords

laboratory monitoring
16
drug levels
16
atrial fibrillation
12
fixed doses
12
routine laboratory
12
dose adjustment
12
monitoring
9
non-vitamin antagonist
8
antagonist oral
8
patients atrial
8

Similar Publications

Magnetic resonance imaging (MRI) is frequently used to monitor disease progression in multiple sclerosis (MS). This study aims to systematically evaluate the correlation between MRI measures and histopathological changes, including demyelination, axonal loss, and gliosis, in the central nervous system of MS patients. We systematically reviewed post-mortem histological studies evaluating myelin density, axonal loss, and gliosis using quantitative imaging in MS.

View Article and Find Full Text PDF

Effect of terahertz radiation on cells and cellular structures.

Front Optoelectron

January 2025

Institute of Physics, Saratov State University, Saratov, 410012, Russia.

The paper presents the results of modern research on the effects of electromagnetic terahertz radiation in the frequency range 0.5-100 THz at different levels of power density and exposure time on the viability of normal and cancer cells. As an accompanying tool for monitoring the effect of radiation on biological cells and tissues, spectroscopic research methods in the terahertz frequency range are described, and attention is focused on the possibility of using the spectra of interstitial water as a marker of pathological processes.

View Article and Find Full Text PDF

The application of the technique for dorsal median sulcus mapping in intramedullary space occupying surgery: a single-center experience.

Acta Neurochir (Wien)

January 2025

Department of Neurosurgery and Department of Neuroscience, Fujian Key Laboratory of Brain Tumors Diagnosis and Precision Treatment, Xiamen Key Laboratory of Brain Center, the First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, China.

Purpose: To investigate the technique for dorsal median sulcus (DMS) mapping and assess its application value in preserving dorsal columnn (DC) function during intramedullary space occupying surgery based on a single-center experience.

Methods: A retrospective analysis was conducted on 41 cases of intramedullary spinal cord tumor admitted to the Department of Neurosurgery at the First Affiliated Hospital of Xiamen University from March 2017 to August 2023. All included cases underwent intraoperative electrophysiological monitoring, and were divided into a study group (n = 18) and a control group (n = 23), based on whether DMS mapping technique was utilized.

View Article and Find Full Text PDF

Description of current status of implementation and management of cardiac arrest in China.

Sci Rep

January 2025

Emergency Department, The State Key Laboratory for Complex, Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.

Variation in the incidence, survival rate and factors associated with survival after cardiac arrest in China is reported. Some studies have tried to fill the knowledge gap regarding the epidemiology of cardiac arrest in China but were unable to identify reasons for the reported differences. Therefore, the purpose of this study was to describe Chinese management of cardiac arrest, particularly from the perspective of compression, ventilation, monitoring, treatment, and extracorporeal cardiopulmonary resuscitation.

View Article and Find Full Text PDF

The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!