AI Article Synopsis

  • The study aimed to assess the safety and feasibility of using cryoprobes for pleural biopsies compared to traditional forceps.
  • In a pilot study with ten patients, results showed that cryoprobes provided larger tissue samples without increasing complications like bleeding or pain.
  • Overall, cryoprobe biopsies were found to be both safe and effective, suggesting they could be a viable alternative to standard forceps in pleural procedures.

Article Abstract

Background: Pleural biopsy is often obtained in patients with undiagnosed exudative pleural effusion during pleuroscopy. Standard forceps have been traditionally used for the biopsy. Cryoprobes are being increasingly used for transbronchial lung biopsy as they obtain larger specimens and have less crush artifact. However, the safety and feasibility of cryoprobe biopsy compared to standard forceps for pleural biopsy has not been fully assessed.

Objectives: The objective of this study was to demonstrate the safety and feasibility of cryoprobe biopsy in the pleural space using semi-rigid pleuroscopy.

Methods: Patients with idiopathic exudative pleural effusions underwent pleuroscopy. The procedure was done in the endoscopy suite with full barrier precautions and moderate sedation. Pleural biopsies were initially taken with a 2.0-mm saw-toothed forceps followed by a 2.4-mm cryoprobe (ERBECRYO, ERBE, US). The freeze time for each biopsy was 3 s.

Results: There were a total of ten patients, five males and five females. The mean age was 69 years (SD ± 11 years). The mean number of biopsies taken from the parietal pleura using forceps was 4.5 (SD ± 1.5) vs. 3.7 (SD ± 1.4) using cryoprobe. The mean cumulative tissue volume with forceps biopsy was 80 cu. mm; the mean cumulative tissue volume with cryobiopsy was 320 cu. mm, p = 0.007. The diagnostic yields were similar in both the groups. There was no increased incidence of bleeding, chest wall injury, or pain using cryoprobe in any of the patients.

Conclusion: The use of cryoprobe for parietal pleural biopsy via semi-rigid pleuroscopy was feasible and safe in this small pilot study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00408-017-9998-0DOI Listing

Publication Analysis

Top Keywords

safety feasibility
12
pleural biopsy
12
biopsy
10
pleural
8
forceps biopsy
8
biopsy semi-rigid
8
semi-rigid pleuroscopy
8
exudative pleural
8
standard forceps
8
feasibility cryoprobe
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!