Application of Scanning Electron Microscopy With Energy-Dispersive X-Ray Spectroscopy for Analyzing Ocular Surface Particles on Schirmer Strips.

Cornea

*Department of Public Health Sciences, University of Miami, Miami, FL; †Miami Veterans Administration Medical Center, Miami, FL; ‡Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL; §Center for Advanced Microscopy, College of Arts and Sciences, University of Miami, Miami, FL; ¶Miami Project Imaging and Histology Cores, Miami Project to Cure Paralysis, University of Miami, Miami, FL; and ‖Department of Ophthalmology, School of Medicine, University of Maryland, Baltimore, MD.

Published: June 2017

Purpose: To demonstrate the application of scanning electron microscopy with energy-dispersive x-ray spectroscopy (SEM/EDS) for analyzing Schirmer strips for particle concentration, size, morphology, and type distribution.

Methods: A cross-sectional design was used. Patients were prospectively recruited from the Miami Veterans Affairs (VA) Healthcare System eye clinic, and they underwent a complete ocular surface examination. The size, type, and chemical composition of particulate matter on Schirmer strips (from the left eye) were analyzed using SEM/EDS.

Results: Schirmer strips from all 6 patients showed particle loading, ranging from 1 to 33 particles, whereas the blank Schirmer strip that served as a control showed no particle loading. Most particles were coarse, with an average size of 19.7 μm (95% confidence interval 15-24.4 μm). All samples contained organic particles (eg, pollen and mold), and 5 of the 6 samples contained nonorganic particles. The nonorganic particles were composed of silicon, minerals, and metals, including gold and titanium. The size of aluminum and iron particles was ≥62 μm, whereas the size of 2 other metals, zinc and gold, was smaller, that is, <20 μm. Most metal particles were elongated compared with the organic particles, which were round.

Conclusions: Although SEM/EDS has been extensively used in biomedical research, its novel application to assess the size, morphology, and chemical composition of the ocular surface particles offers an unprecedented opportunity to tease out the role of particulate matter exposure in ocular surface disease and disorders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5419879PMC
http://dx.doi.org/10.1097/ICO.0000000000001173DOI Listing

Publication Analysis

Top Keywords

schirmer strips
16
application scanning
8
scanning electron
8
electron microscopy
8
microscopy energy-dispersive
8
energy-dispersive x-ray
8
x-ray spectroscopy
8
ocular surface
8
particle loading
8
samples contained
8

Similar Publications

The Schirmer strip measures tear volume in millimeters. A major limitation of the Schirmer strip is that it does not measure tear volume in a volumetric unit. Furthermore, the linearity range, lower limit of detection (LLOD), and lower limit of quantification (LLOQ) are not established.

View Article and Find Full Text PDF

Objective: To investigate the effects of oral baricitinib on ocular surface disease (OSD) in patients with chronic graft-versus-host disease (cGVHD).

Design: Prospective phase 1 to 2 single institution trial.

Subjects: Eighteen patients with ocular graft-versus-host-disease (oGVHD) and systemic steroid-refractory cGVHD.

View Article and Find Full Text PDF
Article Synopsis
  • Tear fluid is a useful source for biomarker discovery, but challenges like small sample volume and inconsistent collection methods hinder its analysis.
  • The study introduces a new high-throughput method for processing tear fluid using just 0.5 μL, which simplifies handling and reduces processing time compared to traditional approaches.
  • This method achieved a four-fold increase in the number of proteins identified, demonstrating the effectiveness of microcapillary collection and the potential for improved biomarker discovery in tear proteomics.
View Article and Find Full Text PDF

Candidate Tear-Based Uveitis Biomarkers in Children with JIA Based on Arthritis Activity and Topical Corticosteroid Use.

Ocul Immunol Inflamm

November 2024

Division of Rheumatology, Cincinnati Children's Hospital Medical Center and Department of Pediatrics, University of Cincinnati, Cincinnati, Ohio, USA.

Background: Uveitis is an inflammatory ocular disease secondary to disruption of the retinal pigmented epithelium (RPE) and blood retinal barrier (BRB). Known clinical factors do not accurately predict uveitis risk in Juvenile Idiopathic Arthritis (JIA). Tear fluid is easily obtained for biomarker study.

View Article and Find Full Text PDF

Background: New biomarkers that improve diagnosis of Alzheimer's disease (AD) are warranted. Tear fluid (TF) containing variety of proteins that reflect pathophysiological changes of systemic diseases makes TF proteins potential biomarker candidates for AD.

Objective: We investigated the expression levels of TF proteins in persons with mild AD and cognitively healthy controls (CO) to find out if altered proteins may link to the AD pathophysiology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!