A new retinal reattachment surgical procedure is based on a stent that is deployed to press the retina back in place. An eye-stent finite element model studied the strain induced by the stent on retina. Finite element model simulations were performed for several stent geometric configurations (number of loops, wire diameter, and intraocular pressure). The finite element model was validated against experiment. Parametric studies demonstrated that stents could be successfully designed so that the maximum strain would be below permanent damage strain threshold of 2%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/cnm.2885 | DOI Listing |
Front Bioeng Biotechnol
January 2025
Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Orthopaedics, The Affiliated Hospital of Guizhou Medical University, Guiyang, China.
Background: Microfracture drilling is a surgical technique that involves creating multiple perforations in areas of cartilage defects to recruit stem cells from the bone marrow, thereby promoting cartilage regeneration in the knee joint. Increasing the exposed bone marrow surface area (more holes in the same area) can enhance stem cell outflow. However, when the exposed area is large, it may affect the mechanical strength of the bone at the site of the cartilage defect.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Mathematics, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalganj, 8100, Bangladesh.
The numerical analysis examines the attributes of magnetohydrodynamic natural convection in a closed cavity including a circular hollow. Because mono and hybrid nanofluids have many applications in thermal engineering and manufacturing, hybrid nanofluids are utilized as the substance within the entire domain. The investigation centers on a closed, trapezoidal-shaped hollow with a heated surface ring.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Armament Engineering, College of Engineering, Ethiopian Defence University, Bishoftu, P.O. Box 1041, Ethiopia.
Advanced materials are crucial for enhancing soldier safety through improved personal body armor. In contrast to conventional Kevlar-epoxy composites, this study examines the ballistic performance of a unique ECO-UHMWPE (Ultra-High Molecular Weight Polyethylene) vest. The aim is to achieve a lightweight design with superior impact resistance, addressing limitations of the current armor used by the Ethiopian Defense Force.
View Article and Find Full Text PDFOrthop Surg
January 2025
Department of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China.
Objective: Inferior pole patellar fractures (IPPFs) pose a significant challenge due to their complex fracture patterns and high risk of complications associated with current treatment methods. This study aims to (1) characterize the fracture patterns of IPPFs using fracture mapping and (2) compare the biomechanical stability and clinical outcomes of treatment with anchor suture with patellar cerclage versus Kirschner-wire tension band combined with patellar cerclage.
Methods: (1) A retrospective analysis was conducted on 61 patients with IPPF.