Clinical Judgment Is Not Reliable for Reducing Whole-body Computed Tomography Scanning after Isolated High-energy Blunt Trauma.

Anesthesiology

From the Grenoble Alpes Trauma Center, Pôle Anesthésie-Réanimation, CHU Grenoble Alpes, Grenoble, France (T.M., J-F.P., P.B.); Université Grenoble Alpes, Grenoble, France (T.M., V.B., J-L.B., G.F., J-F.P., P.B.); INSERM U1216, Grenoble, France (T.M., J-F.P., P.B.); Département de Médecine d'Urgence, CHU Grenoble Alpes, Grenoble, France (V.B., L.S.); Pôle Recherche, CHU Grenoble Alpes, Grenoble, France (J-L.B.); Pole Imagerie, CHU Grenoble Alpes, Grenoble, France (G.F., F.T.); Divisions of Trauma Anesthesiology and Critical Care Medicine, Department of Anesthesiology, R Adams Cowley Shock Trauma Center, Baltimore, Maryland (S.M.G.).

Published: June 2017

Background: The purpose of this study was to test the diagnostic performance of clinical judgment for the prediction of a significant injury with whole-body computed tomography scanning after high-energy trauma.

Methods: The authors conducted an observational prospective study in a single level-I trauma center. Adult patients were included if they had an isolated high-energy injury. Senior trauma leaders were asked to make a clinical judgment regarding the likelihood of a significant injury before performance of a whole-body computed tomography scan. Clinical judgments were recorded using a probability diagnosis scale. The primary endpoint was the diagnosis of a serious-to-critical lesion on the whole-body computed tomography scan. Diagnostic performance was assessed using receiver operating characteristic analysis.

Results: Of the 354 included patients, 127 patients (36%) had at least one injury classified as abbreviated injury score greater than or equal to 3. The area under the receiver operating characteristic curve of the clinical judgment to predict a serious-to-critical lesion was 0.70 (95% CI, 0.64 to 0.75%). The sensitivity of the clinical judgment was 82% (95% CI, 74 to 88%), and the specificity was 49% (95% CI, 42 to 55%). No patient with a strict negative clinical examination had a severe lesion (n = 19 patients). The sensitivity of the clinical examination was 100% (95% CI, 97 to 100%) and its specificity was 8% (95% CI, 5 to 13%).

Conclusions: Clinical judgment alone is not sufficient to reduce whole-body computed tomography scan use. In patients with a strictly normal physical examination, whole-body computed tomography scanning might be avoided, but this result deserves additional study in larger and more diverse populations of trauma patients.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ALN.0000000000001617DOI Listing

Publication Analysis

Top Keywords

clinical judgment
24
whole-body computed
24
computed tomography
24
tomography scanning
12
tomography scan
12
clinical
9
isolated high-energy
8
diagnostic performance
8
serious-to-critical lesion
8
receiver operating
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!