Model-based dose calculation algorithms (MBDCAs) have recently emerged as potential successors to the highly practical, but sometimes inaccurate TG-43 formalism for brachytherapy treatment planning. So named for their capacity to more accurately calculate dose deposition in a patient using information from medical images, these approaches to solve the linear Boltzmann radiation transport equation include point kernel superposition, the discrete ordinates method, and Monte Carlo simulation. In this overview, we describe three MBDCAs that are commercially available at the present time, and identify guidance from professional societies and the broader peer-reviewed literature intended to facilitate their safe and appropriate use. We also highlight several important considerations to keep in mind when introducing an MBDCA into clinical practice, and look briefly at early applications reported in the literature and selected from our own ongoing work. The enhanced dose calculation accuracy offered by a MBDCA comes at the additional cost of modelling the geometry and material composition of the patient in treatment position (as determined from imaging), and the treatment applicator (as characterized by the vendor). The adequacy of these inputs and of the radiation source model, which needs to be assessed for each treatment site, treatment technique, and radiation source type, determines the accuracy of the resultant dose calculations. Although new challenges associated with their familiarization, commissioning, clinical implementation, and quality assurance exist, MBDCAs clearly afford an opportunity to improve brachytherapy practice, particularly for low-energy sources.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5346608 | PMC |
http://dx.doi.org/10.5114/jcb.2017.65849 | DOI Listing |
Drug Des Devel Ther
January 2025
Department of Hematology, Jining NO. 1 People's Hospital, Jining, 272000, People's Republic of China.
Purpose: Mitoxantrone (MTX) is largely restricted in clinical usage due to its significant cardiotoxicity. Multiple studies have shown that an imbalance in the gut-heart axis plays an important role in the development of cardiovascular disease (CVD). We aim to explore the possible correlations between gut microbiota (GM) compositions and cardiometabolic (CM) disorder in MTX-triggered cardiotoxicity mice.
View Article and Find Full Text PDFInt J Biomed Imaging
January 2025
Medical Imaging Sciences Department, College of Health Sciences, Gulf Medical University, Ajman, UAE.
The quality of CT images obtained from hepatocellular carcinoma (HCC) patients is complex, affecting diagnostic accuracy, precision, and radiation dose assessment due to increased exposure risks. The study evaluated image quality qualitatively and quantitatively by comparing quality levels with an effective radiation dose to ensure acceptable quality accuracy. This study retrospectively reviewed 100 known HCC patients (Li-RADS-5) who underwent multidetector computed tomography (MDCT) multiphasic scans for follow-up of their health condition between January and October 2023.
View Article and Find Full Text PDFCureus
December 2024
Gastroenterology, St Mark's Hospital and Academic Institute, London, GBR.
The therapeutic failure of infliximab therapy remains a challenge in patients with inflammatory bowel disease (IBD), and dose optimization is often required. Accelerated or intensified regimes showed value in treating patients in the acute setting with high CRP or low albumin levels, which are suggested by recent guidelines; however, evidence is weak. Therapeutic drug monitoring (TDM), with anti-tumor necrosis factor-alpha (TNF-α) trough levels and antibodies, showed value during maintenance therapy, but not in induction and can guide clinical decisions in patients that might be undertreated with the standard dosing regimen.
View Article and Find Full Text PDFJ Med Virol
February 2025
Department of Infectious Diseases, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
The determinants of varicella-zoster virus (VZV)-associated central nervous system (CNS) infection have not been fully elucidated. This study aimed to investigate the incidence and risk factors, including immunosuppression, for different manifestations of VZV-associated CNS infection. Patient registers were used to include adults diagnosed with VZV-associated CNS infections between 2010 and 2019 in Sweden.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Chemistry, Faculty of Science, Hokkaido University, Sapporo, Hokkaido, Japan.
Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.
Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!