A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioanalysis of farnesyl pyrophosphate in human plasma by high-performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry and hybrid quadrupole Orbitrap high-resolution mass spectrometry. | LitMetric

Bioanalysis of farnesyl pyrophosphate in human plasma by high-performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry and hybrid quadrupole Orbitrap high-resolution mass spectrometry.

Anal Bioanal Chem

Drug Metabolism and Pharmacokinetics Research Laboratories, Pharmaceutical Research Division, Takeda Pharmaceutical Company Limited, 26-1, Muraoka-Higashi 2-chome, Fujisawa, Kanagawa, 251-8555, Japan.

Published: May 2017

The isoprenoids farnesyl pyrophosphate (FPP) and geranylgeranyl pyrophosphate (GGPP) are pivotal intermediates for cholesterol homeostasis and cell signaling in the mevalonate pathway. We developed a sensitive and selective high-performance liquid chromatography tandem triple quadrupole mass spectrometry (LC-QQQ-MS) method for FPP in human plasma without the need for a derivatization process. We optimized the sample preparation procedure to extract FPP and C-FPP (as internal standard) from sample fluids using methanol. Phosphate-buffered saline was used as the surrogate matrix for the preparation of calibration curves and quality control samples. Using an XBridge C18 column (3.5 μm, 2.1 × 100-mm ID) with gradient elution composed of 10 mmol/L ammonium carbonate/ammonium hydroxide (1000:5, v/v) and acetonitrile/ammonium hydroxide (1000:5, v/v) provided the sharp peaks of FPP and C-FPP in human plasma. The calibration curve ranged from 0.2 to 20 ng/mL in human plasma with acceptable intra-day and inter-day precision and accuracy. The sensitivity of this bioanalytical method was sufficient for clinical analysis. The endogenous FPP plasma concentrations in 40 human healthy volunteers ascertained by LC-QQQ-MS and high-performance liquid chromatography tandem hybrid quadrupole Orbitrap high-resolution mass spectrometry (LC-Q-Orbi-MS) were comparable. Furthermore, the endogenous GGPP in human plasma was selectively detected for the first time by LC-Q-Orbi-MS. In conclusion, a sensitive bioanalytical method for FPP in human plasma by means of LC-QQQ-MS and LC-Q-Orbi-MS was developed in this study. Taking into account the versatility of LC-Q-Orbi-MS, the simultaneous detection of FPP and GGPP may be feasible in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-017-0293-yDOI Listing

Publication Analysis

Top Keywords

human plasma
24
mass spectrometry
16
high-performance liquid
12
liquid chromatography
12
farnesyl pyrophosphate
8
triple quadrupole
8
hybrid quadrupole
8
quadrupole orbitrap
8
orbitrap high-resolution
8
high-resolution mass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!