A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Association of cardiac resynchronization therapy with the incidence of appropriate implantable cardiac defibrillator therapies in ischaemic and non-ischaemic cardiomyopathy. | LitMetric

Aims: Cardiac resynchronization therapy (CRT) reduces the incidence of sudden cardiac death and the use of appropriate implantable cardioverter-defibrillator (ICD) therapies (AICDTs); however, this antiarrhythmic effect is only observed in certain groups of patients. To gain insight into the effects of CRT on ventricular arrhythmia (VA) burden, we compared the incidence of AICDT use in four groups of patients: patients with ischaemic cardiomyopathy vs. non-ischaemic dilated cardiomyopathy (NIDC) and patients implanted with an ICD vs. CRT-ICD.

Methods And Results: We analysed 689 consecutive patients (mean follow-up 37 ± 16 months) included in the Umbrella registry, a multicentre prospective registry including patients implanted with ICD or CRT-ICD devices with remote monitoring capabilities in 48 Spanish Hospitals. The primary outcome was the time to first AICDT. Despite a worse clinical risk profile, NIDC patients receiving a CRT-ICD had a lower cumulative probability of first AICDT use at 2 years compared with patients implanted with an ICD [24.7 vs. 41.6%, hazard ratio (HR): 0.49, P = 0.003]; on the other hand, there were no significant differences in the incidence of first AICDT use at 2 years in ischaemic patients (22.6 vs. 21.9%, P = NS). Multivariate analysis confirmed the association of CRT with lower AICDT rates amongst NIDC patients (Adjusted HR: 0.55, CI 95% 0.35-0.87).

Conclusions: These data suggest that CRT is associated with significantly lower rates of first AICDT use in NIDC patients, but not in ischaemic patients. This study suggests that ICD patients with NIDC and left bundle branch block experiencing VAs may benefit from an upgrade to CRT-ICD despite being in a good functional class.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euw303DOI Listing

Publication Analysis

Top Keywords

nidc patients
16
patients
13
patients implanted
12
implanted icd
12
cardiac resynchronization
8
resynchronization therapy
8
appropriate implantable
8
groups patients
8
incidence aicdt
8
patients ischaemic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!