Small changes, big effects: The hemodynamics of partial and complete aortic occlusion to inform next generation resuscitation techniques and technologies.

J Trauma Acute Care Surg

From the Department of Emergency Medicine (M.A.J.), University of California Davis Medical Center, Sacramento, California; Department of Surgery (A.J.D., R.M.R., S.-A.E.F., L.P.N.), University of California Davis Medical Center, Sacramento, California; Clinical Investigation Facility, David Grant USAF Medical Center (O.G.), Travis Air Force Base, California; The Norman M. Rich Department of Surgery (T.E.R.), the Uniformed Services University of the Health Sciences, Bethesda, Marland; Department of General Surgery (L.P.N.), David Grant USAF Medical Center, Travis Air Force Base, California; Department of General Surgery (L.P.N.), Uniformed Services University of the Health Sciences, Bethesda, Maryland; and Heart, Lung and Vascular Center (T.K.W.), David Grant USAF Medical Center, Travis Air Force Base, California.

Published: June 2017

Background: The transition from complete aortic occlusion during resuscitative endovascular balloon occlusion of the aorta can be associated with hemodynamic instability. Technique refinements and new technologies have been proposed to minimize this effect. In order to inform new techniques and technology, we examined the relationship between blood pressure and aortic flow during the restoration of systemic circulation following aortic occlusion at progressive levels of hemorrhage.

Methods: An automated supraceliac aortic clamp, capable of continuously variable degrees of occlusion, was applied in seven swine. The swine underwent stepwise removal of 40% of their total blood volume in four equal aliquots. After each aliquot, progressive luminal narrowing to the point of complete aortic occlusion was achieved over 5 minutes, sustained for 5 minutes, and then released over 5 minutes. Proximal and distal blood pressure and distal aortic flow were continuously recorded throughout the study.

Results: Upon release of the clamp, hyperemic aortic flow was observed following 10% and 20% hemorrhage (1,599 ± 785 mL/min, p < 0.01; and 1,070 ± 396 mL/min, p < 0.01, respectively). Proximal blood pressure exhibited a nonlinear relationship to aortic flow during clamp removal; however, distal blood pressure increased linearly with distal flow upon clamp opening across all hemorrhage volumes.

Conclusions: Hyperemic blood flow following return of circulation may contribute to cardiovascular collapse. Reintroduction of systemic blood flow after aortic occlusion should be guided by distal blood pressure rather than proximal pressure. Awareness of hemodynamic physiology during aortic occlusion is of paramount importance to the clinical implementation of next-generation resuscitative endovascular balloon occlusion of the aorta techniques and technologies.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0000000000001446DOI Listing

Publication Analysis

Top Keywords

aortic occlusion
24
blood pressure
20
aortic flow
16
complete aortic
12
distal blood
12
aortic
11
occlusion
9
techniques technologies
8
resuscitative endovascular
8
endovascular balloon
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!