A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transcarotid Artery Revascularization With Flow Reversal. | LitMetric

Transcarotid Artery Revascularization With Flow Reversal.

J Endovasc Ther

1 Department of Vascular Surgery and Endovascular Therapy, Augusta Hospital and Catholic Hospital Group, Düsseldorf, Germany.

Published: April 2017

Purpose: To report a study evaluating the safety and efficacy of stenting via direct carotid access with flow reversal using the ENROUTE Transcarotid Neuroprotection System.

Methods: Between March 2009 and June 2012, 75 patients (mean age 72.6 years; 45 men) underwent carotid artery stenting with the ENROUTE System; the majority of patients (63, 84%) were asymptomatic. The primary safety endpoint was the composite of major stroke, myocardial infarction, or death at 30 days. Efficacy outcomes included acute device success, procedure success, and tolerance to flow reversal. Fifty-six (74.7%) patients underwent diffusion-weighted magnetic resonance imaging (DW-MRI) before and after the procedure to assess the development of new ischemic brain lesions.

Results: Acute device and procedure success were achieved in 68 (90.6%) patients. The reverse flow circuit was established in 71 (94.6%) patients; only 5 patients demonstrated transient intolerance to flow reversal that did not interfere with completion of the procedure. The mean time on flow reversal was 19.1 minutes. In the DW-MRI substudy, 10 (17.9%) of 56 patients had ipsilateral new white lesions with a mean volume of 0.17 mL. At 30 days, no major stroke, myocardial infarction, or death occurred; 1 patient had experienced a minor stroke that was adjudicated as not related to either the device or procedure.

Conclusion: Results of the PROOF study demonstrate the safety and efficacy of transcarotid revascularization with the ENROUTE Transcarotid Neuroprotection System.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1526602817693607DOI Listing

Publication Analysis

Top Keywords

flow reversal
20
safety efficacy
8
enroute transcarotid
8
transcarotid neuroprotection
8
major stroke
8
stroke myocardial
8
myocardial infarction
8
infarction death
8
acute device
8
procedure success
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!