Awake and/or freely moving small animal single photon emission imaging allows the continuous study of molecules exhibiting slow kinetics without the need to restrain or anaesthetise the animals. Estimating motion free projections in freely moving small animal planar imaging can be considered as a limited angle tomography problem, except that we wish to estimate the 2D planar projections rather than the 3D volume, where the angular sampling in all three axes depends on the rotational motion of the animal. In this study, we hypothesise that the motion corrected planar projections estimated by reconstructing an estimate of the 3D volume using an iterative motion compensating reconstruction algorithm and integrating it along the projection path, will closely match the true, motion-less, planar distribution regardless of the object motion. We tested this hypothesis for the case of rigid motion using Monte-Carlo simulations and experimental phantom data based on a dual opposed detector system, where object motion was modelled with 6 degrees of freedom. In addition, we investigated the quantitative accuracy of the regional activity extracted from the geometric mean of opposing motion corrected planar projections. Results showed that it is feasible to estimate qualitatively accurate motion-corrected projections for a wide range of motions around all 3 axes. Errors in the geometric mean estimates of regional activity were relatively small and within 10% of expected true values. In addition, quantitative regional errors were dependent on the observed motion, as well as on the surrounding activity of overlapping organs. We conclude that both qualitatively and quantitatively accurate motion-free projections of the tracer distribution in a rigidly moving object can be estimated from dual opposed detectors using a correction approach within an iterative reconstruction framework and we expect this approach can be extended to the case of non-rigid motion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/aa68cd | DOI Listing |
Data Brief
February 2025
Universidad Nacional de Asunción, Instituto de Investigaciones en Ciencias de la Salud, San Lorenzo 111421, Paraguay.
This article presents 582 bone scan images from 291 adult patients who attended the Nuclear Medicine Service at the Instituto de Investigaciones en Ciencias de la Salud (IICS) of the Universidad Nacional de Asunción (UNA), Paraguay, between 2020 and 2024. The images were acquired using trimodal SPECT-CT-PET equipment, model AnyScan SCP, and the MEDISO brand. Approximately 20 mCi of technetium-99m methylene diphosphonate (Tc-MDP) was administered to each patient, producing whole-body planar images in anterior and posterior projections of the axial and appendicular skeleton with a resolution of 256 × 1024 pixels.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
Siemens Healthineers AG, Forchheim, Germany.
Purpose: Digital breast tomosynthesis (DBT) has been introduced more than a decade ago. Studies have shown higher breast cancer detection rates and lower recall rates, and it has become an established imaging method in diagnostic settings. However, full-field digital mammography (FFDM) remains the most common imaging modality for screening in many countries, as it delivers high-resolution planar images of the breast.
View Article and Find Full Text PDFiScience
December 2024
Faculty of Geography, Yunnan Normal University, Kunming 650500, China.
The topography of the border ecological barrier area in southern Yunnan is complex, and utilizing the vertically projected area to estimate carbon stocks may lead to significant errors. This study uses multisource data and multiple models to investigate the spatial and temporal variations in surface carbon stocks and the factors affecting them in the study area. Results show: The difference between the surface area and planar area in the study area is large, and the spatial and temporal changes of surface land use and carbon stock based on this are more significant, showing an inverted V-shape trend in time and a spatial distribution pattern of "high southeast, low northwest".
View Article and Find Full Text PDFZhonghua Jie He He Hu Xi Za Zhi
December 2024
Department of Radiology, People's Hospital of Lanshan District, Linyi276002, China.
This study aimed to assess the diagnostic value of the airway post-processing technique of multi-slice spiral CT(MSCT) in Accessory cardiac bronchus(ACB)and to improve the understanding of this disease. The original MSCT axial images and various post-processing reconstructed images of 9 ACB cases were retrospectively analyzed.Airway post-processing techniques, including multi-planar reformation(MPR), minimum intensity projection (MinIP), volume rendering technique(VRT), CT virtual endoscopy(CTVE) and tissue transition projection (TTP), were employed.
View Article and Find Full Text PDFMolecules
October 2024
Department of Architectural Engineering, Hanyang University ERICA, 55 Hanyangdaehak-ro, Sangrok-gu, Ansan-si 15588, Gyeonggi-do, Republic of Korea.
Corrosion of metallic equipment is a critical issue across various industries, necessitating the development of advanced protective strategies. This study utilized dispersion-corrected density functional theory (DFT) with Becke-Johnson D3(BJ) to examine the atomic-level adsorption of quinoxalinones on Fe(110) surfaces, focusing on optimizing substitution strategies to enhance corrosion inhibition. Three quinoxalinones, quinoxalin-2(1H)-one (QNO), 3-methylquinoxalin-2(1H)-one (QNOM), and 3,7-dimethylquinoxalin-2(1H)-one (QNO2M), were investigated in various configurations and protonation states.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!