A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionb9ohlra5cc0udvk6krgg8d0am6tj2h50): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

Scaling effects in spiral capsule robots. | LitMetric

Scaling effects in spiral capsule robots.

Proc Inst Mech Eng H

1 Department of Mechanical and Electrical Engineering, Changsha University, Changsha, China.

Published: April 2017

Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 to 10 m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411917693660DOI Listing

Publication Analysis

Top Keywords

spiral capsule
24
capsule robots
12
capsule robot
12
spiral
9
fluid
9
robot
9
blood vessels
8
computational fluid
8
fluid dynamics
8
dynamics method
8

Similar Publications

/: Inhaler devices have been developed for the effective delivery of inhaled medications used in the treatment of pulmonary diseases. However, differing operating procedures across the devices can lead to user errors and reduce treatment efficacy, especially when patients use multiple devices simultaneously. To address this, we developed a novel dry powder inhaler (DPI), combining fluticasone propionate (FP), salmeterol xinafoate (SX), and tiotropium bromide (TB) into a single device designed for bioequivalent delivery compared to existing commercial products in an animal model.

View Article and Find Full Text PDF

Objective: To observe the clinical efficacy of 's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.

Methods: A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, 's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks.

View Article and Find Full Text PDF

Purpose Of The Study: improving the surgical treatment of biliary pancreatitis by using a universal retractor and improved methods of omentobursostomy with drainage of the omental bursa.

Study Design: Non-randomized controlled clinical trial Material and methods: This study included thirty-nine patients who underwent surgical procedures between October 2022 and September 2023 in Semey, located in the Abay region. The study examined the general characteristics of surgical interventions performed for acute biliary pancreatitis using our proposed treatment methods and devices to improve the outcomes of acute biliary pancreatitis.

View Article and Find Full Text PDF

Beginning in 2006, optical coherence tomography (OCT) has been adapted for use as a vibrometer for hearing research. The application of OCT in this field, particularly for studying cochlear mechanics, represents a revolutionary advance over previous technologies. OCT provides detailed evidence of the motions of components within the organ of Corti, extending beyond the first-encountered surface of observation.

View Article and Find Full Text PDF

Purpose: The Myxozoa class is characterized by parasites that have valves joined by a suture line and polar capsules containing eversible spiral filamento and this class is considered an obligate parasite. The genus Ceratomyxa has approximately 300 species described in fish, both marine and freshwater fish, mainly infecting the gallbladder, but also occurring in the urinary bladder. This study describes a new species of Ceratomyxa in the Amazon region for Pimelodella cristata.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!