Background: It remains unclear whether radial access increases the risk of operator or patient radiation exposure compared to transfemoral access when performed by expert operators.
Objectives: This study sought to determine whether radial access increases radiation exposure.
Methods: A total of 8,404 patients, with or without ST-segment elevation acute coronary syndrome, were randomly assigned to radial or femoral access for coronary angiography and percutaneous intervention, and collected fluoroscopy time and dose-area product (DAP). RAD-MATRIX is a radiation sub-study of the MATRIX (Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of AngioX) trial. We anticipated that 13 or more operators, each wearing a thorax (primary endpoint), wrist, and head (secondary endpoints) lithium fluoride thermoluminescent dosimeter, and randomizing at least 13 patients per access site, were needed to establish noninferiority of radial versus femoral access.
Results: Among 18 operators, performing 777 procedures in 767 patients, the noninferiority primary endpoint was not achieved (p value for noninferiority = 0.843). Operator equivalent dose at the thorax (77 μSv) was significantly higher with radial than femoral access (41 μSv; p = 0.02). After normalization of operator radiation dose by fluoroscopy time or DAP, the difference remained significant. Radiation dose at wrist or head did not differ between radial and femoral access. Thorax operator dose did not differ for right radial (84 μSv) compared to left radial access (52 μSv; p = 0.15). In the overall MATRIX population, fluoroscopy time and DAP were higher with radial compared to femoral access: 10 min versus 9 min (p < 0.0001) and 65 Gy·cm versus 59 Gy·cm (p = 0.0001), respectively.
Conclusions: Compared to femoral access, radial access is associated with greater operator and patient radiation exposure when performed by expert operators in current practice. Radial operators and institutions should be sensitized towards radiation risks and adopt adjunctive radioprotective measures. (Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of AngioX; NCT101433627).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2017.03.018 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
Department of Cardiology, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Background: Access-related vascular complications (VCs) after percutaneous transfemoral transcatheter aortic valve replacement (TAVR) are associated with poor clinical outcomes and remain a significant challenge despite technological advances. The aim of this study was to identify anatomic predictors of access-related VCs after TAVR on preprocedural contrast-enhanced multidetector computed tomography (MDCT).
Aims: The aim of this study was to identify anatomical predictors of access-related VCs after TAVR on preprocedural contrast-enhanced MDCT.
Indian Heart J
January 2025
Department of Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bangalore, India.
Background: Cardiac catheterization via the trans-radial approach (TRA) has shown several advantages over the trans-femoral approach (TFA) but with a concern of higher radiation exposure. Considering the growing experience with TRA, this study compares patient's radiation during coronary angiography using TRA versus TFA.
Methods: This study included consecutive patients undergoing coronary angiogram over a year at tertiary hospital performed by experienced operators through radial or femoral access.
Curr Probl Cardiol
January 2025
International arrhythmia center, Fundacion cardioinfatil - La Cardio, Division of Cardiology, Bogota, Colombia. Electronic address:
Introduction: Electrophysiologic (EP) procedures are typically performed via the femoral venous system, but in some patients, the inferior vena cava (IVC) is unavailable. The hepatic vein has emerged as a viable alternative to femoral access, providing an inferior route that accommodates large sheaths required for better catheter manipulation. Although the percutaneous transhepatic approach has been used successfully in the pediatric population, its use in adults is scarce, with a complication rate of approximately 5%.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", 80131 Naples, Italy.
The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners.
View Article and Find Full Text PDFArch Bone Jt Surg
January 2024
Orthopedic Research Center, Department of Orthopedic Surgery, Mashhad University of Medical sciences, Mashhad, Iran.
Second-generation large-diameter head hip resurfacing (HR) arthroplasty has gained popularity in terms of its potential for minimal wear and the preservation of proximal femoral bone stock. HR faces challenges, such as increased hip fracture rates and adverse reactions to metal detritus, despite the fact that over one million metal-on-metal (MoM) arthroplasties have been performed globally. FDA issued warnings in 2011 and 2016 regarding higher failure rates in women and categorized MoM implants as high-risk, influencing U.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!