A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy and reliability of cetacean cranial measurements using computed tomography three dimensional volume rendered images. | LitMetric

AI Article Synopsis

  • Computed tomography (CT) offers a modern, accurate method for measuring the cranial dimensions of cetaceans post-mortem, reducing reliance on traditional manual measurement techniques.
  • A study evaluated CT three-dimensional volume rendered images (3DVRI) from 9 stranded cetaceans, demonstrating high accuracy in cranial measurements (88.05%-99.64%) compared to manual methods.
  • The results showed strong reproducibility and repeatability of the measurements using intraclass correlation coefficients (ICC), suggesting that CT 3DVRI could effectively serve as a reliable alternative for cranial analysis in cetaceans and aid in establishing reference data for research.

Article Abstract

Computed tomography (CT) has become more readily available for post-mortem examination, offering an alternative to cetacean cranial measurements obtained manually. Measurement error may result in possible variation in cranial morphometric analysis. This study aimed to evaluate the accuracy and reliability of cetacean cranial measurements obtained by CT three-dimensional volume rendered images (3DVRI). CT scans of 9 stranded cetaceans were performed. The acquired images were reconstructed using bone reconstruction algorithms. The reconstructed crania obtained by 3DVRI were visualized after excluding other body structures. Accuracy of cranial measurements obtained by CT 3DVRI was evaluated by comparing with that obtained by manual approach as standard of reference. Reproducibility and repeatability of cranial measurements obtained by CT 3DVRI were evaluated using intraclass correlation coefficient (ICC). The results demonstrated that cranial measurements obtained by CT 3DVRI yielded high accuracy (88.05%- 99.64%). High reproducibility (ICC ranged from 0.897 to 1.000) and repeatability (ICC ranged from 0.919 to 1.000 for operator 1 and ICC range from 0.768 to 1.000 for operator 2) were observed in cranial measurements obtained by CT 3DVRI. Therefore, cranial measurements obtained by CT 3DVRI could be considered as virtual alternative to conventional manual approach. This may help the development of a normative reference for current cranial maturity and discriminant analysis studies in cetaceans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5362215PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0174215PLOS

Publication Analysis

Top Keywords

cranial measurements
32
measurements 3dvri
20
cetacean cranial
12
cranial
10
accuracy reliability
8
reliability cetacean
8
measurements
8
computed tomography
8
volume rendered
8
rendered images
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!