Predicting the Maximum Dynamic Strength in Bench Press: The High Precision of the Bar Velocity Approach.

J Strength Cond Res

1NAR-Nucleus of High Performance in Sport, São Paulo, Brazil;2Department of Mechatronics Engineering, University of São Paulo, São Paulo, Brazil;3CBRu-Brazilian Rugby Confederation, São Paulo, Brazil; and4State University of Londrina, Londrina, Paraná, Brazil.

Published: April 2017

Loturco, I, Kobal, R, Moraes, JE, Kitamura, K, Cal Abad, CC, Pereira, LA, and Nakamura, FY. Predicting the maximum dynamic strength in bench press: the high precision of the bar velocity approach. J Strength Cond Res 31(4): 1127-1131, 2017-The aim of this study was to determine the force-velocity relationship and test the possibility of determining the 1 repetition maximum (1RM) in "free weight" and Smith machine bench presses. Thirty-six male top-level athletes from 3 different sports were submitted to a standardized 1RM bench press assessment (free weight or Smith machine, in randomized order), following standard procedures encompassing lifts performed at 40-100% of 1RM. The mean propulsive velocity (MPV) was measured in all attempts. A linear regression was performed to establish the relationships between bar velocities and 1RM percentages. The actual and predicted 1RM for each exercise were compared using a paired t-test. Although the Smith machine 1RM was higher (10% difference) than the free weight 1RM, in both cases the actual and predicted values did not differ. In addition, the linear relationship between MPV and percentage of 1RM (coefficient of determination ≥95%) allow determination of training intensity based on the bar velocity. The linear relationships between the MPVs and the relative percentages of 1RM throughout the entire range of loads enable coaches to use the MPV to accurately monitor their athletes on a daily basis and accurately determine their actual 1RM without the need to perform standard maximum dynamic strength assessments.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000001670DOI Listing

Publication Analysis

Top Keywords

maximum dynamic
12
dynamic strength
12
bench press
12
bar velocity
12
smith machine
12
1rm
10
predicting maximum
8
strength bench
8
press high
8
high precision
8

Similar Publications

Objective: This study aimed to investigate how dynamic contrast-enhanced CT imaging signs correlate with the differentiation grade and microvascular invasion (MVI) of hepatocellular carcinoma (HCC), and to assess their predictive value for MVI when combined with clinical characteristics.

Methods: We conducted a retrospective analysis of clinical data from 232 patients diagnosed with HCC at our hospital between 2021 and 2022. All patients underwent preoperative enhanced CT scans, laboratory tests, and postoperative pathological examinations.

View Article and Find Full Text PDF

Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.

Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).

View Article and Find Full Text PDF

The thermodynamic properties of frozen soil depend on its temperature state and ice content. Additionally, the permeability coefficient significantly affects both the temperature distribution and water movement. In this study, the dynamic variation of soil permeability coefficient with temperature is considered, the permeability coefficient is defined as a piecewise function with temperature as independent variable, and the hydrothermal coupling equation is established.

View Article and Find Full Text PDF

A Schiff base-functionalized chitosan magnetic bio-nanocomposite for efficient removal of Pb (II) and Cd (II) ions from aqueous solutions.

Int J Biol Macromol

January 2025

Department of Chemistry, Faculty of Science, Arak University, Arak 38481-77584, Iran; Institute of Nanosciences &Nanotechnology, Arak University, Arak, Iran. Electronic address:

The rapid industrialization and human activities in catchments have posed notable global challenges in removing of heavy metal contaminants from wastewater. Here, Schiff-bases (SB) of cyanoguanidine (CG) and salicylaldehyde (SA) were covalently grafted on a magnetic nanocomposite of chitosan to form a hybrid magnetic nanostructure (FeO@CS-CGSB). The synthesized structure was characterized using various techniques such as Fourier transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (SEM), transmission electron microscopy (TEM), powder X-ray diffraction (XRD), thermogravimetric analysis (TGA), vibrating sample magnetometry (VSM), dynamic light scattering (DLS), zeta potential, and Brunauer-Emmett-Teller surface area analysis (BET).

View Article and Find Full Text PDF

Objective: To assess the dynamic mandibular movement of patients with condylar hyperplasia before and after simultaneous orthognathic surgery and condylectomy through an intraoral approach.

Methods: Two groups of patients diagnosed with unilateral condylar hyperplasia were studied: the preoperative group consisted of 23 patients and the postoperative group consisted of 13 patients who had undergone simultaneous orthognathic surgery and condylectomy through an intraoral approach with follow-up for more than 1 year. The normal reference value was obtained from 11 individuals without oral and maxillofacial diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!