A method for separating IL-1 from plasma inhibitors by silica extraction has been developed and coupled to a highly sensitive bioassay using the LBRM TG6 cell line and the I1-2 dependent HT2A cell line. Using this assay we have detected IL-1 activity in plasma from patients undergoing elective surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0022-1759(88)90399-7 | DOI Listing |
JMIR Public Health Surveill
January 2025
Center for Global Health, University of New Mexico Health Sciences Center, Albuquerque, NM, United States.
Background: Numerous studies have assessed the risk of SARS-CoV-2 exposure and infection among health care workers during the pandemic. However, far fewer studies have investigated the impact of SARS-CoV-2 on essential workers in other sectors. Moreover, guidance for maintaining a safely operating workplace in sectors outside of health care remains limited.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Emergency Department, Tel Aviv Sourasky Medical Center, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Objective: To evaluate the NEXUS Chest CT ALL decision instrument (DI) in reducing unnecessary chest CT imaging in minor blunt trauma patients while preserving high sensitivity for detecting clinically meaningful injuries. Additionally, we examined the impact of delayed presentation, chronic disease, and anticoagulation/anti-aggregation medications on trauma outcomes.
Methods: This retrospective study included 853 adult minor blunt trauma patients who underwent chest CT in the emergency department (ED) of Tel-Aviv Sourasky Medical Center between 2018 and 2022.
J Physiol
January 2025
Université Paris Cité, CNRS, Saints-Pères Paris Institute for the Neurosciences, Paris, France.
Fañanas cells (FCs) are cerebellar glia of unknown function. First described more than a century ago, they have been almost absent from the scientific literature ever since. Here, we combined whole-cell, patch clamp recordings, near-UV laser photolysis, dye-loading and confocal imaging for a first characterization of FCs in terms of their morphology, electrophysiology and glutamate-evoked currents.
View Article and Find Full Text PDFAnal Chem
January 2025
Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.
View Article and Find Full Text PDFJ Intern Med
January 2025
Department of Anesthesiology and Intensive Care Medicine (CCM, CVK), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Background: Five fulfilled hemophagocytic lymphohistiocytosis (HLH)-2004 criteria, and the HScore are widely used and recommended by international expert consensus to diagnose secondary HLH. Both diagnostic scores have never been validated in heterogeneous patient cohorts of secondary HLH patients. We aimed to systematically optimize and validate diagnostic criteria of secondary HLH using a multicenter approach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!