Biomechanical analysis of lateral interbody fusion strategies for adjacent segment degeneration in the lumbar spine.

Spine J

Department of Neurological Surgery, Keck School of Medicine, University of Southern California, 1520 San Pablo St, Suite 3800, Los Angeles, CA 90033, USA.

Published: July 2017

Background Context: Surgical treatment of symptomatic adjacent segment disease (ASD) typically involves extension of previous instrumentation to include the newly affected level(s). Disruption of the incision site can present challenges and increases the risk of complication. Lateral-based interbody fusion techniques may provide a viable surgical alternative that avoids these risks. This study is the first to analyze the biomechanical effect of adding a lateral-based construct to an existing fusion.

Purpose: The study aimed to determine whether a minimally invasive lateral interbody device, with and without supplemental instrumentation, can effectively stabilize the rostral segment adjacent to a two-level fusion when compared with a traditional posterior revision approach.

Study Design/setting: This is a cadaveric biomechanical study of lateral-based interbody strategies as add-on techniques to an existing fusion for the treatment of ASD.

Methods: Twelve lumbosacral specimens were non-destructively loaded in flexion, extension, lateral bending, and torsion. Sequentially, the tested conditions were intact, two-level transforaminal lumbar interbody fusion (TLIF) (L3-L5), followed by lateral lumbar interbody fusion procedures at L2-L3 including interbody alone, a supplemental lateral plate, a supplemental spinous process plate, and then either cortical screw or pedicle screw fixation. A three-level TLIF was the final instrumented condition. In all conditions, three-dimensional kinematics were tracked and range of motion (ROM) was calculated for comparisons. Institutional funds (<$50,000) in support of this work were provided by Medtronic Spine.

Results: The addition of a lateral interbody device superadjacent to a two-level fusion significantly reduced motion in flexion, extension, and lateral bending (p<.05). Supplementing with a lateral plate further reduced ROM during lateral bending and torsion, whereas a spinous process plate further reduced ROM during flexion and extension. The addition of posterior cortical screws provided the most stable lateral lumbar interbody fusion construct, demonstrating ROM comparable with a traditional three-level TLIF.

Conclusions: The data presented suggest that a lateral-based interbody fusion supplemented with additional minimally invasive instrumentation may provide comparable stability with a traditional posterior revision approach without removal of the existing two-level rod in an ASD revision scenario.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2017.03.005DOI Listing

Publication Analysis

Top Keywords

interbody fusion
16
lateral interbody
8
adjacent segment
8
lateral-based interbody
8
lumbar interbody
8
interbody
7
fusion
6
lateral
5
biomechanical analysis
4
analysis lateral
4

Similar Publications

Background: Oblique lumbar interbody fusion (OLIF) results in less tissue damage than in other surgeries, but immediate postoperative pain occurs. Notably, facet joint widening occurs in the vertebral body after OLIF. We hypothesized that the application of a facet joint block to the area of widening would relieve facet joint pain.

View Article and Find Full Text PDF

Background: A limited number of studies have compared the outcomes of anterior lumbar interbody fusion (ALIF) to transforaminal lumbar interbody fusion (TLIF) for the treatment of isthmic spondylolisthesis. This study aims to compare postoperative complications between these two surgical approaches.

Methods: A retrospective review was performed using a large national database.

View Article and Find Full Text PDF

Cost-Utility of Lumbar Interbody Fusion Surgery: A Systematic Review.

Spine J

January 2025

Hoag Orthopedics, 16300 Sand Canyon Ave., Suite. 500, Irvine, CA 92618, United States. Electronic address:

Background Context: Lumbar interbody fusion (LIF) is a common surgical intervention for treating lumbar degenerative disorders. Increasing demand has contributed to ever-increasing healthcare expenditure and economic burden. To address this, cost-utility analyses (CUAs) compare value in the context of patient outcomes.

View Article and Find Full Text PDF

Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.

Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.

View Article and Find Full Text PDF

Background Context: Correcting sagittal malalignment in adult spinal deformity (ASD) is a challenging task, often requiring complex surgical interventions like pedicle subtraction osteotomies (PSOs). Different types of three-column osteotomies (3COs), including Schwab 3, Schwab 4, Schwab 4 with interbody cages, and the "sandwich" technique, aim to optimize alignment and fusion outcomes. The role of interbody cages in enhancing fusion and segmental correction remains unclear.