A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of biometry and intraocular lens power calculation performed by a new optical biometry device and a reference biometer. | LitMetric

Comparison of biometry and intraocular lens power calculation performed by a new optical biometry device and a reference biometer.

J Cataract Refract Surg

From the Cullen Eye Institute (B.V. Ventura, Wang, Koch, Weikert), Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA; Altino Ventura Foundation (B.V. Ventura, M.C. Ventura), HOPE Eye Hospital (B.V. Ventura, M.C. Ventura), Recife, and the Department of Ophthalmology (B.V. Ventura), Federal University of São Paulo, São Paulo, Brazil.

Published: January 2017

AI Article Synopsis

  • The study aimed to compare the measurements and IOL power calculations of a new biometer (Galilei G6) against a reference biometer (IOLMaster 500) in cataract patients.
  • Conducted in a private practice in Recife, Brazil, the study analyzed biometric data from 88 eyes, focusing on variables like axial length, keratometry, and anterior chamber depth.
  • Results showed that while the two devices produced similar averages for these measurements, the significant variation suggests they should not be used interchangeably for precise calculations.

Article Abstract

Purpose: To compare biometry measurements and intraocular lens (IOL) power calculations obtained by a new optical A-scan interferometer biometer (Galilei G6) (new biometer) and a partial coherence interferometer biometer (IOLMaster 500) (reference biometer).

Setting: Private practice, Recife, Brazil.

Design: Retrospective comparative study.

Methods: Cataract patients who had biometric measurements with the new biometer and the reference biometer were included in the study. Comparisons were performed for axial length (AL), keratometry (K), anterior chamber depth (ACD), and IOL power calculation to reach emmetropia with an Acrysof SN60WF IOL using the Haigis formula. The Pearson correlation coefficient and the 95% limits of agreement (LoA) were calculated. The paired Student t test and the Wilcoxon test were used to assess differences between devices.

Results: Eighty-eight eyes (88 patients) were studied. Both biometers provided statistically similar mean IOL power to reach emmetropia, AL, keratometry, and ACD measurements (P > .05). The differences in these variables did not vary as their mean values increased, and there was a strong positive correlation between the values obtained by both devices for each variable. The 95% LoA values for AL, mean keratometry, ACD, and IOL power were 0.27 mm, 1.08 diopters (D), 0.66 mm, and 1.56 D, respectively.

Conclusions: The 2 devices were comparable with regard to mean IOL power, mean AL, K, and ACD measurements. However, the wide range of differences between the devices suggests they should not be used interchangeably.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2016.11.033DOI Listing

Publication Analysis

Top Keywords

iol power
20
intraocular lens
8
power calculation
8
reference biometer
8
interferometer biometer
8
acd iol
8
reach emmetropia
8
keratometry acd
8
acd measurements
8
power
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!