New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEEK has the potential to reduce tibial insert thickness and preserve bone in the knee. This study investigated the wear performance of PEEK and CFR-PEEK in a low conformity total knee replacement configuration. Custom-made flat inserts were tested against cobalt-chromium femoral bearings in a knee wear simulation for a period of three million cycles. Wear was assessed gravimetrically at intervals throughout the study. The wear rates of both PEEK and CFR-PEEK were very high and almost two orders of magnitude higher than the wear rate of UHMWPE under comparable conditions. Evidence of mechanical failure of the materials, including surface cracking and delamination was observed in both materials. This study highlights that these materials may not be suitable alternatives for UHMWPE in low-conformity designs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5328191PMC
http://dx.doi.org/10.1016/j.wear.2016.12.010DOI Listing

Publication Analysis

Top Keywords

peek cfr-peek
16
bearing materials
8
total knee
8
knee replacement
8
wear
8
experimental wear
8
joint replacement
8
wear simulation
8
peek
5
materials
5

Similar Publications

Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).

Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.

View Article and Find Full Text PDF

Surgeons' perspective on the use of carbon fibre plates for extremity fracture fixation.

Eur J Orthop Surg Traumatol

November 2024

Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Leeds, UK.

Introduction/purpose: Carbon fibre plating (CFR-PEEK) became available to orthopaedic surgeons in 1998 as a competitor to the traditional metal implants. Despite this, the use of such implants has been limited globally. The aim of this study was therefore to explore the barriers to more widespread use of CFR-PEEK, specifically by examining orthopaedic surgeons' perceptions and opinions of its use through a cross-sectional survey.

View Article and Find Full Text PDF

Cranial reconstruction utilizing polymeric implants in two different designs: finite element investigation.

BMC Musculoskelet Disord

November 2024

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Introduction: Impact loads applied to the human head can result in skull fractures or other injuries that require a craniectomy. The removed portion is replaced with biological or synthetic materials using cranioplasty surgery. Titanium has been the material of choice for cranial implants due to its superior properties and biocompatibility; however, its issues have prompted the search for substitute materials (e.

View Article and Find Full Text PDF

Aim: This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy.

Material And Method: Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to compare the biomechanical performance of polyetheretherketone (PEEK) and titanium alloys in fixation systems for reconstructing mandibular defects after surgeries due to tumors or trauma using finite element analysis.
  • - In the analysis, PEEK materials (including unmodified, glass fiber-reinforced, and carbon fiber-reinforced) generated more stress on the mandible than titanium alloys, with glass fiber-reinforced PEEK being particularly problematic as it exceeded the mandible’s yield strength.
  • - The conclusion was that carbon fiber-reinforced PEEK showed better stress distribution and stability, making it the most suitable material for mandibular defect repair in fixation systems, as prolonged low stress can lead to bone issues.*
View Article and Find Full Text PDF