Objectives: To determine the ultrasound elasticity of the brain in neonates METHODS: Strain elastography was performed in 21 healthy neonates (mean gestational age [GA], 34 weeks; range, 28-40 weeks). Elastographic scores were assigned to the following structures on a 5-point color scale (1-5): ventricle, periventricular white matter, caudate, subcortical, cortical gray matter, and subdural space. Three elastographic images were evaluated in each patient, and median elastographic scores were calculated. The scores were compared between regions and were correlated with the corrected GA. Interobserver agreements for assignment of elastographic scores were analyzed.
Results: The ventricle and subdural space showed an elasticity score of 1 in all patients. The cortical gray matter (median, 3.0; first-third quartiles, 2.33-3.33) showed higher elasticity compared to the periventricular white mater (4.0; 3.00-4.00; P < .001), caudate (4.3; 3.67-4.67; P < .001), and subcortical white matter (4.0; 4.00-4.00; P < .001). The caudate showed lower elasticity compared to periventricular white matter (P = .004). The periventricular white matter showed higher elasticity compared to subcortical white matter (P = .009). There was a positive trend between the corrected GA and cortical gray matter elastographic score (γ = 0.376; P = .093). Interobserver agreement was moderate to almost perfect (κ = 0.53-0.89).
Conclusions: Neonatal intracranial regions showed different elasticity, which could be accessed by strain elastography. These normal findings should prompt future studies investigating the use of ultrasound elastography in the neonatal brain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7863/ultra.16.06079 | DOI Listing |
Br J Radiol
January 2025
Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
Diagnostics (Basel)
August 2024
Life-Beauty-Private Company, 05-825 Grodzisk Mazowiecki, Poland.
Background: Cellulite is a cosmetic defect of multifactorial etiology that affects over 90% of women worldwide. Cellulite-induced skin changes are undesirable and negatively affect self-esteem. Despite a plethora of cellulite-reducing treatments, we still lack objective tools to enable accurate diagnosis and treatment efficacy assessment.
View Article and Find Full Text PDFVet Sci
August 2024
Department of Surgery, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand.
Canine multicentric lymphoma (CML) is a prevalent hematopoietic neoplasm that initially responds well to treatment but often relapses due to chemotherapy resistance. Evaluation of treatment response is essential for effective management. Ultrasound (US) can differentiate between benign and lymphomatous lymph nodes (LLNs).
View Article and Find Full Text PDFJ Clin Ultrasound
November 2024
Department of Radiology, Clínica Alta (DASA), Rio de Janeiro, Brazil.
Objective: The objectives of this study were to evaluate the vascularization pattern of uterine myoma (UM) by ultrasonography using Superb Microvascular Imaging (SMI) and tissue stiffness elastography.
Method: A prospective and cross-sectional study was carried out between March 2020 and December 2022 among women with clinical and ultrasound diagnosis of UM who would subsequently undergo radiofrequency ablation. Ultrasound examination was performed using both transvaginal and transabdominal routes.
Jpn J Ophthalmol
September 2024
Medical School, University of Crete, Heraklion, Greece.
Purpose: This study evaluated the role of shear wave elastography imaging (SWEΙ) in uveal melanomas and the associations between SWEI and clinical and hemodynamic findings.
Study Design: Prospective, clinical study METHODS: Twelve patients with uveal melanomas, scheduled to undergo Ru-106 brachytherapy, were prospectively recruited from the Department of Ophthalmology of the University Hospital of Heraklion (September-December 2022). B-mode, hemodynamic and SWEI ultrasonography examinations were performed with the HiScan (OPTIKON 2000) and the LOGIQ E9 (GE Healthcare) sonographic systems, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!