Purpose: To assess current practices in digital mammography (DM) in Portuguese healthcare providers using digital systems. To investigate compliance with European standards regarding mean glandular dose and quality control practice and to identify optimisation needs.
Methods: Two questionnaires, targeted at breast radiographers and chief radiographers, were designed and applied in 65 imaging departments offering DM. Questions fielded were focused on the staff profile and technical/clinical practice.
Results: Prior to starting their activity in DM, 70% (82 out of 118) of the respondents received training in DM. The practice in 29 out of 59 providers was established by the manufacturers' recommendations for image acquisition. Variations were observed between radiographers who belong to the same provider namely the selection of exposure parameters such as the target-filter combination and automatic mode. The use of the manual exposure mode was reported for imaging breast implants (44%) and surgical specimens (22%). The main causes of repeat examinations were skin folding (21%) and absence of pectoral muscle (PM) (20%).
Conclusions: The study revealed opportunities to optimise radiographers' practice in DM regarding the selection of exposure parameters. A robust and consistent training programme in DM and established local protocols can help to reduce the variations observed and improve clinical practice.
Main Messages: • Radiographers adopted different practices selecting AEC modes and T/F combinations. • Radiographer practice is more consistent using DR than using CR systems. • The main causes for rejecting images were the visibility of skin folding and PM absence. • Radiographers were partly unaware of the dose indicator. • Radiographers' training needs: QC, interventional procedures and breast dose optimisation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5438316 | PMC |
http://dx.doi.org/10.1007/s13244-017-0550-9 | DOI Listing |
J Neurosurg Spine
January 2025
2Cleveland Clinic Center for Spine Health, Cleveland Clinic, Cleveland; and.
Objective: Spinal fusion is a commonly performed surgical procedure used to relieve pain, deformity, and instability of various spinal pathologies. Although there have been attempts to standardize spinal fusion assessment radiologically, there is currently no unified definition that also considers clinical symptomology. This review attempts to create a more holistic and standardized definition of spinal fusion.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: Coronectomy is a valuable treatment proven safe for non-pathological mandibular third molars with an increased risk of inferior alveolar nerve injury. Coronectomy may also be useful for mandibular third molars with dentigerous cysts and caries, but this is not commonly performed due to the lack of well-designed, evidence-based studies. Here, we aim to investigate the safety of coronectomy for mandibular third molars with caries and dentigerous cysts.
View Article and Find Full Text PDFJ Imaging
January 2025
Diagnostic Imaging Department, Latifa Hospital, Dubai Health, Dubai P.O. Box 2727, United Arab Emirates.
Chest and abdomen radiographs are the most common radiograph examinations conducted in the Dubai Health sector, with both involving exposure to several radiosensitive organs. Diagnostic reference levels (DRLs) are accepted as an effective safety, optimization, and auditing tool in clinical practice. The present work aims to establish a comprehensive projection and weight-based structured DRL system that allows one to confidently highlight healthcare centers in need of urgent action.
View Article and Find Full Text PDFBioengineering (Basel)
January 2025
Department of Information Management, Chung Yuan Christian University, Taoyuan City 320317, Taiwan.
In dental diagnosis, evaluating the severity of periodontal disease by analyzing the radiographic defect angle of the intrabony defect is essential for effective treatment planning. However, dentists often rely on clinical examinations and manual analysis, which can be time-consuming and labor-intensive. Due to the high recurrence rate of periodontal disease after treatment, accurately evaluating the radiographic defect angle of the intrabony defect is vital for implementing targeted interventions, which can improve treatment outcomes and reduce recurrence.
View Article and Find Full Text PDFEur Urol
January 2025
Department of Oncology, City of Hope Cancer Center, Goodyear, AZ, USA.
Background And Objective: Selection of patients harboring mutations in homologous recombination repair (HRR) genes for treatment with a PARP inhibitor (PARPi) is challenging in metastatic castration-resistant prostate cancer (mCRPC). To gain further insight, we quantitatively assessed the differential efficacy of PARPi therapy among patients with mCRPC and different HRR gene mutations.
Methods: This living meta-analysis (LMA) was conducted using the Living Interactive Evidence synthesis framework.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!