A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.33.313DOI Listing

Publication Analysis

Top Keywords

sequential injection
8
injection chromatography
8
monolithic column
8
low-pressure separation
8
α-tocopherol γ-oryzanol
8
chromatography ultra-short
4
ultra-short monolithic
4
column low-pressure
4
separation
4
separation α-tocopherol
4

Similar Publications

The unique optical properties of perovskite quantum dots (PQDs), particularly the tunable photoluminescence (PL) across the visible spectrum, make them a promising tool for chlorinated detection. However, the correlation between the fluorescence emission shift behavior and the interface of phase transformation in PQDs has not been thoroughly explored. In this study, we synthesized CsPbBr PQDs via the hot-injection method and demonstrated their ability to detect chlorinated volatile compounds such as HCl and NaOCl through a halide exchange process between the PQDs' solid thin film and the chlorinated vapor phase.

View Article and Find Full Text PDF

Background: Ozurdex® (Allergan®, AbbVie Company, North Chicago, Illinois, EUA), is composed of 0.7 mg of dexamethasone, fused in a solid biodegradable PLGA polymer, whose degradation occurs naturally in the vitreous cavity, usually in six months after its application.

Methods: In this study, we included patients aged ≥ 18 years with one or two eyes who had an indication for Ozurdex implants.

View Article and Find Full Text PDF

Understanding the pattern of resistance in multi-drug resistant clinical isolates of Acinetobacter baumannii based on metabolomics approach.

Microb Pathog

January 2025

HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi-75270, Pakistan; Dr. Panjwani Center for Molecular Medicine and Drug Research (PCMD), International Center for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi-75270, Pakistan. Electronic address:

Antimicrobial resistance (AMR) poses significant challenges to global public health. The major cause of AMR development is previous use of antibiotics, hospitalization, and the lack of efficient methods for screening AMR pathogens. Mass spectrometry techniques offer rapid, sensitive, and early detection of AMR both on proteomics and metabolomics levels.

View Article and Find Full Text PDF

Acoustic frequency comb generation on a composite diamond/silicon microcantilever in ambient air.

Microsyst Nanoeng

January 2025

Institute of Novel Semiconductors, State Key Laboratory of Crystal Materials, Shandong University, 27 South Shanda Road, Shandong, 250100, P. R. China.

Acoustic frequency combs (AFCs) contain equidistant coherent signals with unconventional possibilities on metrology. Previously, implementation of AFCs on mechanical microresonators with large air damping loss is difficult, which restricted their atmospheric applications. In this work, we explore the potentials of a composite diamond/silicon microcantilever for parametric generation of AFCs in ambient air.

View Article and Find Full Text PDF

Single-Injection Composite Tracer Achieves Intraoperative Dual-Tracing and Precise Localization of Sentinel Lymph Nodes.

ACS Appl Mater Interfaces

January 2025

Sixth People's Hospital, School of Medicine & School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China.

The use of dual-tracer contrast agents in clinical applications, such as sentinel lymph node (SLN) identification, offers significant advantages including enhanced accuracy, sensitivity, as well as comprehensive and multimodal visualization. In the current clinical practice, SLNs are typically marked prior to surgical resection by multiple and sequential injections of two tracers, the radioactive tracer and methylene blue (MB) dye. This imposes physical and psychological burden on patients and medical staff.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!