Purpose: B mapping is important for many quantitative imaging protocols, particularly those that include whole-brain T mapping using the variable flip angle (VFA) technique. However, B mapping sequences are not typically available on many magnetic resonance imaging (MRI) scanners. The aim of this work was to demonstrate that B mapping implemented using standard scanner product pulse sequences can produce B (and VFA T ) maps comparable in quality and acquisition time to advanced techniques.
Materials And Methods: Six healthy subjects were scanned at 3.0T. An interleaved multislice spin-echo echo planar imaging double-angle (EPI-DA) B mapping protocol, using a standard product pulse sequence, was compared to two alternative methods (actual flip angle imaging, AFI, and Bloch-Siegert shift, BS). Single-slice spin-echo DA B maps were used as a reference for comparison (Ref. DA). VFA flip angles were scaled using each B map prior to fitting T ; the nominal flip angle case was also compared.
Results: The pooled-subject voxelwise correlation (ρ) for B maps (BS/AFI/EPI-DA) relative to the reference B scan (Ref. DA) were ρ = 0.92/0.95/0.98. VFA T correlations using these maps were ρ = 0.86/0.88/0.96, much better than without B correction (ρ = 0.53). The relative error for each B map (BS/AFI/EPI-DA/Nominal) had 95 percentiles of 5/4/3/13%.
Conclusion: Our findings show that B mapping implemented using product pulse sequences can provide excellent quality B (and VFA T ) maps, comparable to other custom techniques. This fast whole-brain measurement (∼2 min) can serve as an excellent alternative for researchers without access to advanced B pulse sequences.
Level Of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1673-1682.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmri.25692 | DOI Listing |
J Magn Reson Imaging
January 2025
Department of Neurology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Background: Central arterial stiffening is associated with brain white matter (WM) damage and gray matter (GM) volume loss in older adults, but little is known about this association from an adult lifespan perspective.
Purpose: To investigate the associations of central arterial stiffness with WM microstructural organization, WM lesion load, cortical thickness, and GM volume in healthy adults across the lifespan.
Study Type: This is a cross-sectional study.
Mater Horiz
January 2025
School of Materials Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, P. R. China.
Multilayer thin films composed of dielectric BaCaZrTiO (BCZT) and oxygen-deficient BCZT (BCZT-OD) were fabricated on (001)-oriented NSTO substrates using the pulsed laser deposition (PLD) technique. Unlike conventional approaches to energy storage capacitors, which primarily focus on compositional or structural modifications, this study explored the influence of the layer sequence and periodicity. The interface between the NSTO substrate and the BCZT-OD layer forms a Schottky barrier, resulting in electric field redistribution across the sublayers of the BCZT/BCZT-OD//(1P) thin film.
View Article and Find Full Text PDFVeg Hist Archaeobot
August 2024
School of Archaeology, University of Oxford, Oxford, UK.
Unlabelled: The R package CropPro is an open-access resource to classify archaeobotanical samples as products and by-products of different stages of the crop processing sequence for large-seeded cereal and pulse crops in south west Asia, Europe and other Mediterranean regions. It builds on ethnographic research and analysis conducted by Jones (Plants and ancient man: studies in palaeoethnobotany. Balkema, Rotterdam, pp 43-61, 1984), (J Archaeol Sci 14:311-323, 1987), (Circaea 6:91-96, 1990) and a modified method by Charles (Environ Archaeol 1:111-122, 1998).
View Article and Find Full Text PDFMagn Reson Med
January 2025
National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA.
Purpose: Two-shot γ-aminobutyric acid (GABA) difference editing techniques have been used widely to detect the GABA H4 resonance at 3.01 ppm. Here, we introduce a single-shot method for detecting the full GABA H2 resonance signal, which avoids contamination from the coedited M macromolecules.
View Article and Find Full Text PDFAm J Obstet Gynecol
January 2025
Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium. Electronic address:
Background: Aspirin has proved its efficacy in reducing the rate of preeclampsia in singleton pregnancy, however, there is discrepancy about the efficient dosage that should be used. While some societies recommend daily 75-81mg, others recommend higher dosage (160mg). This discrepancy is due to the lack of randomized controlled studies that compare these two dosages.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!