Perturbation effects of the carbon fiber-PEEK screws on radiotherapy dose distribution.

J Appl Clin Med Phys

Division of Oncology, Rambam Health Care Campus, Haifa, Israel.

Published: March 2017

Radiation therapy, in conjunction with surgical implant fixation, is a common combined treatment in cases of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced Polyetheretherketone (CFR-PEEK) material has been recently introduced for production of intramedullary nails and plates. The purpose of this work was to investigate the perturbation effects of the new CFR-PEEK screws on radiotherapy dose distributions and to evaluate these effects in comparison with traditional titanium screws. The investigation was performed by means of Monte Carlo (MC) simulations for a 6 MV photon beam. The project consisted of two main stages. First, a comparison of measured and MC calculated doses was performed to verify the validity of the MC simulation results for different materials. For this purpose, stainless steel, titanium, and CFR-PEEK plates of various thicknesses were used for attenuation and backscatter measurements in a solid water phantom. For the same setup, MC dose calculations were performed. Next, MC dose calculations for titanium, CFR-PEEK screws, and CFR-PEEK screws with ultrathin titanium coating were performed. For the plates, the results of our MC calculations for all materials were found to be in good agreement with the measurements. This indicates that the MC model can be used for calculation of dose perturbation effects caused by the screws. For the CFR-PEEK screws, the maximum dose perturbation was less than 5%, compared to more than 30% perturbation for the titanium screws. Ultrathin titanium coating had a negligible effect on the dose distribution. CFR-PEEK implants have good prospects for use in radiotherapy because of minimal dose alteration and the potential for more accurate treatment planning. This could favorably influence treatment efficiency and decrease possible over- and underdose of adjacent tissues. The use of such implants has potential clinical advantages in the treatment of bone metastases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689960PMC
http://dx.doi.org/10.1002/acm2.12046DOI Listing

Publication Analysis

Top Keywords

cfr-peek screws
16
perturbation effects
12
dose
9
screws
8
screws radiotherapy
8
radiotherapy dose
8
dose distribution
8
bone metastases
8
dose distributions
8
titanium screws
8

Similar Publications

Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).

Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.

View Article and Find Full Text PDF

Aim: This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy.

Material And Method: Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy.

View Article and Find Full Text PDF

Background: Titanium has been the conventional implant material of choice for fixation in both primary and metastatic spine tumor surgeries (MSTS). However, these implants result in artifact generation during postoperative computed tomography or magnetic resonance imaging, resulting in poor planning of radiotherapy (RT) and suboptimal tumor surveillance. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) implants have gained momentum for instrumentation in MSTS due to their radiolucent properties.

View Article and Find Full Text PDF

Comparison between CFR-PEEK and titanium plate for proximal humeral fracture: A meta-analysis.

Jt Dis Relat Surg

July 2024

Department of Joint Surgery, Tianjin Hospital, No. 406, Jiefang Nan Road, Tianjin, 300211 People's Republic of China.

Objectives: The aim of the present meta-analysis was to compare the efficacy and safety of the carbon fiber-reinforced polyetheretherketone (CFR-PEEK) and titanium plate for the treatment of proximal humeral fractures (PHFs) from clinical comparative trials.

Materials And Methods: A comprehensive search of English databases was carried out, such as PubMed, Web of Science, ScienceDirect, Springer and Cochrane Library databases. The RevMan version 5.

View Article and Find Full Text PDF

Purpose: Implanted devices used in metastatic spine tumor surgery (MSTS) include pedicle screws, fixation plates, fixation rods, and interbody devices. A material to be used to fabricate any of these devices should possess an array of properties, which include biocompatibility, no toxicity, bioactivity, low wear rate, low to moderate incidence of artifacts during imaging, tensile strength and modulus that are comparable to those of cortical bone, high fatigue strength/long fatigue life, minimal or no negative impact on radiotherapy (RT) planning and delivery, and high capability for fusion to the contiguous bone. The shortcomings of Ti6Al4V alloy for these applications with respect to these desirable properties are well recognized, opening the field for an investigation about novel biomaterials that could replace the current gold standard.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!