The aging musculoskeletal system experiences a general decline in structure and function, characterized by a reduced adaptability to environmental stress. We investigated whether the older human Achilles tendon (AT) demonstrates mechanosensitivity (via biomechanical and morphological adaptations) in response to long-term mechanical loading. Thirty-four female adults (60-75 years) were allocated to either a medium-term (14 weeks; =21) high AT strain cyclic loading exercise intervention or a control group (=13), with 12 participants continuing with the intervention for 1.5 years. AT biomechanical properties were assessed using ultrasonography and dynamometry. Tendon cross-sectional area (CSA) was investigated by means of magnetic resonance imaging. A 22% exercise-related increment in ankle plantarflexion joint moment, along with increased AT stiffness (598.2±141.2 versus 488.4±136.9 N mm at baseline), Young's modulus (1.63±0.46 versus 1.37±0.39 GPa at baseline) and about 6% hypertrophy along the entire free AT were identified after 14 weeks of strength training, with no further improvement after 1.5 years of intervention. The aging AT appears to be capable of increasing its stiffness in response to 14 weeks of mechanical loading exercise by changing both its material and dimensional properties. Continuing exercise seems to maintain, but not cause further adaptive changes in tendons, suggesting that the adaptive time-response relationship of aging tendons subjected to mechanical loading is nonlinear.

Download full-text PDF

Source
http://dx.doi.org/10.1242/jeb.146407DOI Listing

Publication Analysis

Top Keywords

mechanical loading
12
achilles tendon
8
loading exercise
8
tendon mechanosensitive
4
mechanosensitive older
4
older adults
4
adults adaptations
4
14 weeks
4
adaptations 14 weeks
4
14 weeks versus
4

Similar Publications

Background: Knee valgus loading is thought to be an important contributor to noncontact anterior cruciate ligament (ACL) injuries, but the effects of training programs focusing on decreasing knee valgus loading on lower extremity biomechanics with respect to ACL injury risk remain unclear. Thus, this study aimed to examine the effect of strength training designed to strengthen the medial thigh muscles on lower extremity joint kinematics, kinetics and muscle activity during single-leg landing.

Methods: A total of 35 healthy participants randomly conducted either exercises targeting medial thigh muscles (intervention group) or exercises that did not target specific lower extremity muscles (control group).

View Article and Find Full Text PDF

Bone mechanical function is determined by multiple factors, some of which are still being elucidated. Here, we present a multivariate analysis of the role of bone tissue composition in the proximal femur stiffness of cadaver bones (n = 12, age 44-93). Stiffness was assessed by testing under loading conditions simulating a sideways fall onto the hip.

View Article and Find Full Text PDF

Implant-supported prosthetic rehabilitation for patients with severely atrophic jaws is challenging due to complex anatomical considerations and the limitations of conventional augmentation techniques. This study explores the potential of subperiosteal (juxta-osseous) implants as an alternative solution, using finite element analysis (FEA) to evaluate mechanical performance. Realistic jaw models, developed from radiographic data, are utilized to simulate various implant configurations and load scenarios.

View Article and Find Full Text PDF

: Unlike road running, mountain and trail running typically cover longer distances and include uphill and downhill segments that impose unique physiological and mechanical demands on athletes. : This study aimed to identify morphological differences in the patellar and Achilles tendons between trail and road runners. Moreover, the potential influence of weekly mileage and accumulated positive elevation gain on the morphology of both tendons was obtained.

View Article and Find Full Text PDF

Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!