Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate patterns and predictors of peripherally inserted central catheter (PICC)-related occlusion.
Materials And Methods: Data from a multihospital study were used to examine factors associated with PICC occlusion. Occlusion was defined if documented in the medical record or when tissue plasminogen activator was administered for occlusion-related concerns. Mixed-effects logistic regression was used to predict occlusion, controlling for patient-, provider-, device-, and hospital-level characteristics.
Results: A total of 14,278 PICCs placed in 13,408 patients were included. Of these, occlusion developed in 1,716 PICCs (12%) in 1,684 patients. The most common indications for PICC insertion were intravenous antibiotic therapy (32.7%), difficult intravenous access (21.5%), and central access (13.7%). PICCs placed in the right arm had decreased odds of occlusion compared with those in the left arm (odds ratio [OR] = 0.82; 95% confidence interval [CI] = 0.72-0.94). Verification of catheter tip position following insertion was associated with reduction in occlusion (OR = 0.75; 95% CI = 0.61-0.92). Although normal saline solution or heparin flushes did not reduce occlusion, PICCs flushed with normal saline solution and "locked" with heparin were less likely to become occluded (OR = 0.54; 95% CI = 0.33-0.88). Compared with single-lumen devices, double- and triple-lumen PICCs were associated with greater incidences of occlusion (double, OR = 3.07; 95% CI = 2.56-3.67; triple, OR = 3.72; 95% CI = 2.92-4.74). Catheter tip malposition was also associated with occlusion (OR = 1.46; 95% CI = 1.14-1.87).
Conclusions: Several patient, provider, and device characteristics appear associated with PICC occlusion. Interventions targeting these factors may prove valuable in reducing this complication.