AI Article Synopsis

Article Abstract

RaySearch RayStation Fallback (FB) planning module can generate an equivalent backup radiotherapy treatment plan facilitating treatment on other linear accelerators. FB plans were generated from the RayStation FB module by simulating the original plan target and organ at risk (OAR) dose distribution and delivered in various backup linear accelerators. In this study, helical tomotherapy (HT) backup plans used in Varian TrueBeam linear accelerator were generated with the RayStation FB module. About 30 patients, 10 with lung cancer, 10 with head and neck (HN) cancer, and 10 with prostate cancer, who were treated with HT, were included in this study. Intensity-modulated radiotherapy Fallback plans (FB-IMRT) were generated for all patients, and three-dimensional conformal radiotherapy Fallback plans (FB-3D) were only generated for lung cancer patients. Dosimetric comparison study evaluated FB plans based on dose coverage to 95% of the PTV volume (R), PTV mean dose (D), Paddick's conformity index (CI), and dose homogeneity index (HI). The evaluation results showed that all IMRT plans were statistically comparable between HT and FB-IMRT plans except that PTV HI was worse in prostate, and PTV R and HI were worse in HN multitarget plans for FB-IMRT plans. For 3D lung cancer plans, only the PTV R was statistically comparable between HT and FB-3D plans, PTV D was higher, and CI and HI were worse compared to HT plans. The FB plans using a TrueBeam linear accelerator generally offer better OAR sparing compared to HT plans for all the patients. In this study, all cases of FB-IMRT plans and 9/10 cases of FB-3D plans were clinically acceptable without further modification and optimization once the FB plans were generated. However, the statistical differences between HT and FB-IMRT/3D plans might not be of any clinically significant. One FB-3D plan failed to simulate the original plan without further optimization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689873PMC
http://dx.doi.org/10.1002/acm2.12032DOI Listing

Publication Analysis

Top Keywords

plans
18
lung cancer
12
fb-imrt plans
12
plans ptv
12
helical tomotherapy
8
raystation fallback
8
fallback planning
8
linear accelerators
8
plans generated
8
generated raystation
8

Similar Publications

Factors Associated With Semaglutide Initiation Among Adults With Obesity.

JAMA Netw Open

January 2025

Department of Global Health, School of Public Health, Boston University, Boston, Massachusetts.

Importance: Semaglutide, a novel glucagon-like peptide-1 (GLP-1) receptor agonist medication, was approved for weight management in individuals with obesity in June 2021. There is limited evidence on factors associated with uptake among individuals in this subgroup without diabetes.

Objective: To explore factors associated with semaglutide initiation among a population of commercially insured individuals with obesity but no diagnosed diabetes.

View Article and Find Full Text PDF

Importance: Timely access to care is a key metric for health care systems and is particularly important in conditions that acutely worsen with delays in care, including surgical emergencies. However, the association between travel time to emergency care and risk for complex presentation is poorly understood.

Objective: To evaluate the impact of travel time on disease complexity at presentation among people with emergency general surgery conditions and to evaluate whether travel time was associated with clinical outcomes and measures of increased health resource utilization.

View Article and Find Full Text PDF

Purpose: Mesothelin (MSLN) is highly expressed in high grade serous/ endometrioid ovarian cancers (HGOC). Anetumab ravtansine (AR) is an antibody drug conjugate directed at MSLN antigen with a tubulin polymerization inhibitor. We assessed safety, activity and pharmacokinetics of the combination AR/bevacizumab (Bev) (ARB) versus weekly paclitaxel (wP)/Bev (PB) in patients with platinum resistant/refractory HGOC (prrHGOC).

View Article and Find Full Text PDF

Advances in Radiation Oncology in Soft Tissue Sarcoma.

Curr Oncol Rep

January 2025

Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA.

Purpose: To review recent advances with radiation therapy (RT) for soft tissue sarcomas (STS).

Recent Findings: Newer data showcases hypofractionated preoperative RT for soft tissue sarcomas treated with surgery to be safe and effective, however, long-term follow up data is pending. Hypofractionated and dose-escalated RT in patients with unresectable STS is also being studied, for which we remain optimistic given advances in RT planning approaches.

View Article and Find Full Text PDF

Smartphone-based non-invasive detection of salivary uric acid based on the fluorescence quenching of gleditsia sinensis carbon dots.

Mikrochim Acta

January 2025

Guizhou Province, Qianzhi Mingguang Soaphorn Rice Processing Base, Zhijin County, Maochang Town, Bijie CityBijie City, 552103, China.

A smartphone-based non-invasive method was developed for salivary uric acid detection using Gleditsia Sinensis carbon dots (GS-CDs). The GS-CDs synthesized by the one-pot hydrothermal method emitted blue fluorescence at a maximum excitation wavelength of 350 nm and had good fluorescence stability in the presence of different ions, while showing selectivity to uric acid solution. The ability of uric acid (UA) to quench the fluorescent substances present in the GS-CDs, was confirmed through HPLC-FLD and LC-MS, FTIR and XPS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!