A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Range of Movement for Impingement and Dislocation Avoidance in Total Hip Replacement Predicted by Finite Element Model. | LitMetric

Dislocation is a serious complication in total hip replacement (THR). An inadequate range of movement (ROM) can lead to impingement of the prosthesis neck on the acetabular cup; furthermore, the initiation of subluxation and dislocation may occur. The objective of this study was to generate a parametric three-dimensional finite element (FE) model capable of predicting the dislocation stability for various positions of the prosthetic head, neck, and cup under various activities. Three femoral head sizes (28, 32, and 36 mm) were simulated. Nine acetabular placement positions (abduction angles of 25°, 40° and 60° combined with anteversion angles of 0°, 15° and 25°) were analyzed. The ROM and maximum resisting moment (RM) until dislocation were evaluated based on the stress distribution in the acetabulum component. The analysis allowed for the definition of a "safe zone" of movement for impingement and dislocation avoidance in THR: an abduction angle of 40°-60° and anteversion angle of 15°-25°. It is especially critical that the anteversion angle does not fall to 10°-15°. The sequence of the RM is a valid parameter for describing dislocation stability in FE studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5325855PMC
http://dx.doi.org/10.1007/s40846-016-0210-4DOI Listing

Publication Analysis

Top Keywords

range movement
8
movement impingement
8
impingement dislocation
8
dislocation avoidance
8
total hip
8
hip replacement
8
finite element
8
element model
8
dislocation stability
8
anteversion angle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!