Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Using digital phantoms as an atlas compared to acquiring CT data for internal radionuclide dosimetry decreases patient overall radiation dose and reduces the required analysis effort and time for organ segmentation. The drawback is that the phantom may not match exactly with the patient. We assessed the effect of varying BMIs on dosimetry results for a bone pain palliation agent, Sm-EDTMP. The simulation was done using the GATE Monte Carlo code. Female XCAT phantoms with the following different BMIs were employed: 18.6, 20.8, 22.1, 26.8, 30.3 and 34.7kg/m. S-factors (mGy/MBq.s) and SAFs (kg) were calculated for the dosimetry of the radiation from major source organs including spine, ribs, kidney and bladder into different target organs as well as whole body dosimetry from spine. The differences in dose estimates from different phantoms compared to those from the phantom with BMI of 26.8kg/m as the reference, were calculated for both gamma and beta radiations. The relative differences (RD) of the S-factors or SAFs from the values of reference phantom were calculated. RDs greater than 10% and 100% were frequent in radiations to organs for photon and beta particles, respectively. The relative differences in whole body SAFs from the reference phantom were 15.4%, 7%, 4.2%, -9.8% and -1.4% for BMIs of 18.6, 20.8, 22.1, 30.3 and 34.7kg/m, respectively. The differences in whole body S-factors for the phantoms with BMIs of 18.6, 20.8, 22.1, 30.3 and 34.7kg/m were 39.5%, 19.4%, 8.8%, -7.9% and -4.3%, respectively. The dosimetry of the gamma photons and beta particles changes substantially with the use of phantoms with different BMIs. The change in S-factors is important for dose calculation and can change the prescribed therapeutic dose of Sm-EDTMP. Thus a phantom with BMI better matched to the patient is suggested for therapeutic purposes where dose estimates closer to those in the actual patient are required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.apradiso.2017.02.044 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!