Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis.

Gait Posture

Institut de Recherche Robert-Sauvé en Santé et en Sécurité du Travail, 505 Boul. Maisonneuve Ouest, H3A 3C2, Montréal, QC, Canada.

Published: May 2017

Portable inertial measurement units (IMUs) are suitable for motion analysis outside the laboratory. However, IMUs depend on the calibration of each body segment to measure human movement. Different calibration approaches have been developed for simplicity of use or similarity to laboratory motion analysis, but they have not been extensively examined. The main objective of the study was to determine the accuracy and repeatability of two common single-pose calibrations (N-pose and T-pose) under different conditions of placement (self-placement and passive placement), as well as their similarity to laboratory analysis based on anatomical landmarks. A further aim of the study was to develop two additional single-pose calibrations (chair-pose and stool-pose) and determine their accuracy and repeatability. Postures and movements of 12 healthy participants were recorded simultaneously with a full-body IMU suit and an optoelectronic system as the criterion measure. Three repetitions of the T-pose and the N-pose were executed by self-placement and passive placement, and three repetitions of the chair-pose and stool-pose were also performed. Repeatability for each single-pose calibration showed an average intraclass correlation coefficient for all axes and joints between 0.90 and 0.94 and a standard error of measurement between 1.5° and 2.1°. The T-pose with passive placement is recommended to reduce longitudinal axis offset error and to increase similarity to laboratory motion analysis. Finally, the chair-pose obtained the least longitudinal axis offset error amongst the tested poses, which shows potential for IMU calibration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2017.02.029DOI Listing

Publication Analysis

Top Keywords

motion analysis
16
accuracy repeatability
12
similarity laboratory
12
passive placement
12
repeatability single-pose
8
single-pose calibration
8
inertial measurement
8
measurement units
8
laboratory motion
8
determine accuracy
8

Similar Publications

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Background: Health systems across Europe are facing a workforce crisis, with some experiencing severe shortages of doctors. In response, many are exploring greater task-sharing, across established professions, such as doctors, nurses, and pharmacists, with patients and carers, and with new occupational groups, in particular ones that can assist doctors and relieve their workload.

Case Presentation: In the early 2000s the United Kingdom created a new occupational role, that of physician assistant.

View Article and Find Full Text PDF

Background: Mobile Health Clinics (MHCs) are an alternate form of healthcare delivery that may ameliorate current rural-urban health disparities in chronic diseases and have downstream impacts on the health system by reducing costs. Evaluations of providers' time allocation on MHCs are scarce, hindering knowledge transfer related to MHC implementation strategies.

Methods: Retrospective economic cost was assessed using business ledgers and expert assessments in 2023 US Dollar (USD) from 2022 to 2023.

View Article and Find Full Text PDF

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

The current gold standard for the study of human movement is the marker-based motion capture system that offers high precision but constrained by costs and controlled environments. Markerless pose estimation systems emerge as ecological alternatives, allowing unobtrusive data acquisition in natural settings. This study compares the performance of two popular markerless systems, OpenPose (OP) and DeepLabCut (DLC), in assessing locomotion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!